► Position the SENSORswitch (A) and tighten the lock nut with
max. 1.5 Nm.
► Connect the SENSORswitch (A) electrically according to the
connection plan.
The plug of the strand variant is intended for one-time
connection.
series10 snap-in assembly
Requirements:
Mounting surface is level and clean (maximum unevenness in
mounting surface 0.1 mm).
The panel is between 1.5 mm and 3.0 mm thick.
► Disconnect the system from its voltage supply and secure it
against being switched on again.
► Set the desired position of the SENSORswitch and drill the hole
according to the drilling pattern.
► In case of a panel thickness of ≥ 2.5 mm, remove the flat seal
(B).
► Slide the O-ring 18x2.2 (E) onto the SENSORswitch.
► Connect the SENSORswitch (A) electrically according to the
connection plan.
► Insert SENSORswitch (A) into the prepared hole and align.
The plug of the strand variant is intended for one-time
connection.
Configure CANEO series10 with IO-Link
TIP
For information on configuring the
SENSORswitch, see our website
series10.captron.com
code.
or scan the QR