Télécharger Imprimer la page

Johnson JSP Serie Guide D'utilisation page 44

Publicité

Les langues disponibles

Les langues disponibles

These data are only indication, you must ask an electrician to determine the exact
data for your pool installation.
Use the cable glands and grommets provided inside the heat pump to route cables.
If the length of your cable is more than 10 meters, we advise you to seek advice
from a professional. A voltage variation of ± 10% during operation is
acceptable. The power supply lines must be securely fastened.
The cable must be suitable for outdoor use.
5.7 Trial running
After connecting water to the pool system, complete with a suitable by-pass and
elec-trical connections by a qualified engineer.
Be sure that:
1) Appliance is horizontal and on a firm base.
2) Water circuit is well connected (no leaks and no chance of injury due to badly fitted
hydraulic couplings).
3) Electrical circuit is well connected (all cables tightened correctly at terminals and
intermediate circuit breaker), insulated and earthed correctly.
4) The installation requirements described previously are strictly adhered to.
ATTENTION: THE HEAT PUMP ONLY FUNCTIONS WHEN WATER FLOW IS
PRESENT.
Then you can start up the heat pump following every point in the below order:
-
Open by-pass valves
-
Start pool system pump
-
Turn on pool heat pump
-
Set regulation
6. OPERATING THE UNIT
Operating the unit comes down to operating the digital controller.
NEVER LET THE DIGITAL CONTROLLER GET WET. THIS MAY CAUSE AN
ELECTRIC SHOCK OR FIRE.
NEVER PRESS THE BUTTONS OF THE DIGITAL CONTROLLER WITH
A HARD, POINTED OBJECT. THIS MAY DAMAGE THE DIGITAL CONTROLLER.
NEVER INSPECT OR SERVICE THE DIGITAL CONTROLLER YOURSELF, ASK
A QUALIFIED SERVICE PERSON TO DO THIS.
12
V.1

Publicité

loading

Ce manuel est également adapté pour:

Jsp08vnJsp12vnJsp15vnJsp23vnJsp29vnJsp34yn