Directives, lois et règlements – Instructions générales et mises en garde
• Operating conditions:
UL 294
• Wiring requirements:
• UL listed or R/C AWM wires that have conductor range of AWG 24-14 shall be used for installation
wiring.
• UL listed or UL recognized connection terminals shall be used for connection of pigtail wires to the
installation wiring. The terminal shall allow connection of AWG 24 wires (pigtail) and gauge of installation
wiring.
• The minimum conductor gauge for connection between the power sourcing equipment (PSE) or power
injector and the powered device (PD) is 26 AWG.
• Minimum PoE category 5e, shielded cable, required for PoE.
• Connectors:
• Power Sources – For UL security applications, when ext. power supply is used the product shall be
powered by a UL 294 or UL 603 listed Class 2 low-voltage power SELV and limited power supply with
appropriate ratings.
• External power to relays – If the relays are connected to an external power source this must be UL 294
listed Class 2 low-voltage power SELV and limited power supply.
• Network Connector – Standard Ethernet wiring. Evaluated by UL when powered from. The 2N product
was tested with the injector Axis 30 W MIDSPAN P/N: 02172-002. The midspan power injector can
be located at any point within the defined structured cabling channel compliant to the Standard for
Balanced Twisted-Pair Telecommunications Cabling and Components, ANSI/TIA-568-C.2, between the
network switch and the powered device (PD).
• System considerations:
• Monitoring software was not evaluated by UL, and is for supplemental use.
• Further information:
• Card formats verified by UL: ISO 14443A, ISO 14443B, ISO 15693, ISO 18092
• Firmware version:
• 2.43.x.x
• Power in:
• Ext. power source , max.
• Power over Ethernet (PoE) IEEE 802.3af (Class 0, max. 12.95 W)
• Power out:
• Active switch output 12 V DC, max.
• I/O interface – I/O functionality:
• 2 Inputs:
• In active mode short-circuited = ON, open = OFF
• In passive mode external voltage in range of –30 V DC to +30 V DC may be applied, U
ON, U
> 1.5 = OFF
IN
• Relay:
• 1x form C relay, NO/NC, max. 1 A, max. 30 V AC/DC
• Installation cable requirements:
• Ext. power: AWG 20-16, qualified for up to 3 m (10 ft)
• Active switch output: AWG 20-16, qualified for up to 3 m (10 ft)
• Relay: AWG 20-16, qualified for up to 3 m (10 ft)
• Inputs: AWG 20-16, qualified for up to 3 m (10 ft)
• Ethernet and PoE: STP CAT 5e or higher, qualified for up to 100 m (328 ft)
-40 °C to +60 °C
Humidity: 10 – 95 % RH
(non-condensing)