Equipment Setup Options
Option # Option Name
120
Schedule Type
200
System Type
205
Equipment Type
218
Reversing Valve
Option Value (factory default in bold)
No Schedule
MO-SU = Every day the same
MO-FR SA SU = 5-1-1 schedule
MO-FR SA-SU = 5-2 schedule
Each Day = Every day different
Note: You can change default MO-FR, SA-SU schedule here. To edit
periods during days, temperature setpoints, or to turn Schedule On/
Off, touch MENU from the Home screen and go to SCHEDULE.
Conventional Forced Air,
Note: This option selects the basic system type your thermostat will
control.
Conventional Forced Air Heat:
High Efficiency Gas,
Standard Gas,
Heat Pump:
Air to Air,
Geothermal
Boiler:
Hot Water,
Steam
Note: This option selects the equipment type your thermostat will
control. Note: This feature is NOT displayed if feature 200 is set to Cool
Only.
O/B on Cool,
0/B on Heat
Note: This option is only displayed if the Heat Pump configured. Select
whether reversing valve O/B should energize in cool or in heat.
20
Heat Pump, Boiler, Cool Only
Oil, Electric, Fan Coil