INSTALLATION
Description
Attic Insulation Shield 12"
Basic Horizontal Termination Kit (A)
Horizontal Termination Kit (B)
Vertical Termination Kit
High Wind Vertical Cap
High Wind Horizontal Cap
Horizontal Square Termination Cap
Vertical Termination Cap
Storm Collar
Adjustable Flashing 0/12-6/12
Adjustable Flashing 6/12-12/12
Vinyl Siding Standoff
Vinyl Siding Shield Plate
Snorkel Termination 14"
Snorkel Termination 36"
Restrictor Disk
Colinear Flex Connectors
FPI
946-604/P
Simpson Direct Vent -Vent Guard (Optional)
770-994
Rigid Pipe Adaptor (Must use with all rigid piping)
946-606
Starter collar reducer 5" x 8" to 4" x 6-5/8"
Note: When using Metal-Fab Sure Seal Rigid Piping - please note that the Adaptor (4DDA) must be used in conjunction with FPI Rigid Pipe Adaptor (510-994).
Offset Pipe Selection: Use this table to determine offset pipe lengths.
Pipe Length
(L)
Run (X)
0" (0mm)
5-11/16" (144mm)
6" (152mm)
8-13/16" (224mm)
9" (229mm)
10-15/16" (278mm)
12" (305mm)
13" (330mm)
24" (610mm)
21-7/16" (697mm)
36" (914mm)
29-13/16" (757mm)
48" (1219mm)
38-1/4" (972mm)
• A Vent Guard is required when the AstroCap is installed above grade at 7 feet or lower.
• The Simpson Dura-Vent and Selkirk Direct Temp horizontal termination caps cannot be used in any applications.
• Only the AstroCap XL and Snorkels are certifi ed for horizontal terminations.
Note: Mettre les conduits d'évacuation horizontaux au niveau ou les installer de façon à ce que leur élévation ne dépasse pas ¼ pouce par pied de conduits jusqu'à la sortie.
S'assurer qu'aucune section du système d'évacuation n'est dirigée vers le bas. Une inclinaison descendante peut provoquer des hausses de température et comporter
un risque d'incendie.
20
Simpson
®
Direct Vent Pro
58DVA-IS
N/A from FPI
N/A
58DVA-KHA
58DVA-VHA
58DVA-VCH
N/A
N/A
N/A
58DVA-SC
58DVA-F6
58DVA-F12
58DVA-VSS
N/A
58DVA-SNK14
58DVA-SNK36 (N/A - FPI)
58DVA-RD
N/A
5" x 8" Venting
Rise (Y)
15-5/16" (389mm)
18-7/16" (468mm)
20-9/16" (522mm)
22-11/16" (576mm)
31-1/16" (789mm)
39-7/16" (1002mm)
47-7/8" (1216mm)
L676 & L900 DIRECT VENT FIREPLACE
Selkirk
Direct Temp™
N/A
5DT-HKA
5DT-HKB
5DT-VKC
N/A
N/A
5DT-HHC
5DT-HVC
5DT-SC
5DT-AF6
5DT-AF12
5DT-VS
5DT-VSP
N/A
N/A
N/A
N/A
946-623/P
946-506/P
946-625
For specifi c instructions on venting components - visit the
manufacturers website listed below.
Simpson Direct Vent Pro: www.duravent.com
Selkirk Direct-Temp: www.selkirkcorp.com
Metal-Fab Sure Seal: www.mtlfab.com
Industrial Chimney Company: www.icc-rsf.com
Note: Horizontal runs of vent must be level, or have a 1/4"
rise for every 1 foot of run towards the termination.
Never allow the vent to run downward - this could cause high
temperatures and may present a possible fi re hazard.
IMPORTANT NOTE
ICC Excel
Metal-Fab™
Sure Seal
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
TM-5VT
N/A
TM-5DHT
5DHT
TM-5HT
5DVT
TM-5VT
5DSC
TM-SC
5DF
TF-5FA
5DF1-2
TF-5FB
5DVS
TM-VSS
N/A
N/A
N/A
TM-5ST14
N/A
TM-5ST36
N/A
TM-5DS
N/A
N/A
AstroCap XL Horizontal Cap
Vent Guard (Optional)
Vinyl Siding Standoff - AstroCap XL
Regency B41XT Foyer à gaz à évent direct
Direct

Publicité

loading

Ce manuel est également adapté pour:

B41xt-ng1B41xt-lp1