Check Before Requiring Services
Symptom
Air conditioner does not run
at all although power is turned
on.
Poor cooling or heating
performance
If your air conditioner still does not work properly although you checked the points as described above, first stop the operation
and turn off the power switch. Then contact your dealer and report the serial number and symptom. Never repair your air
conditioner by yourself since it is very dangerous for you to do so.
■ Tips for Energy Saving
Avoid
Do not block the air intake and outlet of the unit. If either is obstructed, the unit will not work well, and may be damaged.
Do not let direct sunlight into the room. Use sunshades, blinds or curtains. If the walls and ceiling of the room are warmed by the
sun, it will take longer to cool the room.
Do
● Always try to keep the air filter clean. (Refer to "Care and Cleaning".) A clogged filter will impair the performance of the unit.
● To prevent conditioned air from escaping, keep windows, doors and any other openings closed.
NOTE
Should the power fail while the unit is running
If the power supply for this unit is temporarily cut off, the unit will automatically resume operation once power is restored using the same
settings before the power was interrupted.
IMPORTANT INFORMATION REGARDING THE REFRIGERANT USED
This product contains fluorinated greenhouse gases covered by the Kyoto Protocol. Do not vent gases into the atmosphere.
Refrigerant type: R410A
(1)
GWP
value: 1975
(1)
GWP = global warming potential
Periodical inspections for refrigerant leaks may be required depending on European or local legislation.
Please contact your local dealer for more information.
Regarding the amount of refrigerant, see the refrigerant charge label attached to the outdoor unit.
Cause
Power failure or after power failure
Operation button is turned off.
Fuse blow out.
Air intake or air discharge port of indoor
and outdoor units is clogged with dust or
obstacles.
Wind speed switch is set to "Low".
Improper temperature settings
Room is exposed to direct sunlight in
cooling mode.
Doors and /or windows are open.
Air filter is clogged.
Too much heat sources in room in
cooling mode.
Too many people in room in cooling
mode.
Press ON/OFF operation button on remote
controller again.
Switch on power if breaker is turned off.
If breaker has been tripped, consult your dealer
without turning it on.
If blown out, consult your dealer.
Remove dust or obstruction.
Change to "High" or "Strong".
Refer to "■ Tips for Energy Saving".
Refer to "■ Care and Cleaning".
Use minimum heat sources and in a short time.
Reduce temperature settings or change to "High" or
"Strong".
25