CONNECTIONS FOR PERFORMANCE CHECKS
NOTES:
1. REGULATION AND RIPPLE METERS MUST NOT BE GROUNDED THROUGH THREE-WIRE LINE CORD TO GROUND.
2. PERFORM CHECKS WITH LOCAL SENSING CONNECTJONS ONLY.
3. NND30 MODEL IS NOT RECOMMENDED FOR CONSTANT CURRENT LOADS.
4. MAX. CAPTIVATE LOAD RECOMMENDED: 10,000uF EACH OUTPUT.
SAFETY INSTRUCTIONS - NND30:
1. FUSES MUST BE CHANGED BY AUTHORIZED SERVICE PERSONNEL ONLY!
F1:
T3.15A
250V FOR 100/115V~ (SUPPLIED IN THE PACKAGE)
2A
250V FOR 200/230V~ (ASSEMBLED IN THE POWER SUPPLY AT SHIPMENT)
F2:
7A
125V
F3
7A
125V
2. THE POWER SUPPLY SHOULD BE INSTALLED IN SUCH A WAY THAT THE FUSE HOLDER IS NOT OPERATOR ACCESSIBLE.
3. POWER SUPPLY MUST BE SECURED TD THE CHASSIS OF THE END USE EQUIPMENT BY 4 SCREWS INSERTED INTO THREADED
OPENINGS IN THE BOTTOM OF THE PDWER SUPPLY ENCLOSURE (REFER TD OUTLINE DRWG.)
4. MAXIMUM LEAKAGE CURRENT OF END-USE EQUIPMENT SHOULD NOT EXCEED 3.5mA
CE MARK
CE Marking when applied to a product covered by this handbook indicates compliance with the Low Voltage Directive (LVD) of the
European Union in that it complies with EN 60950-1.
A "Declaration of Conformity" in accordance with the preceding directive and standard has been made and is on file at our EU
representative TDK LAMBDA UK, located at Kingsley Avenue, Ilfracombe, Devon EX34 8ES, UK.
The latest revision of EU Declaration of Conformity is available via company web site www.uk.tdk-lambda.com/technical-data
3

Publicité

loading

Ce manuel est également adapté pour:

Nnd301515