MN009517A01-AB
Chapter 3: Operating the Dual-Unit Charger
3.1
Charging Indication
The following table is only applicable when a stand-alone battery is charged in the battery charging pocket.
When charging the battery with device, refer to the display and the LED charging indicator of the device.
Table 5: Charging Indication
LED Indication
Green for approximately one
second
Blinking Amber
Blinking Red
Steady Red
Blinking Green
Steady Green
Off
3.2
Troubleshooting
Table 6: Troubleshooting
Problem
No charger indication
14
Description
Successful charger power-up.
●
Battery is in charger.
●
Battery is waiting to be charged.
●
Battery too hot or too cold
●
Battery is unchargeable or not making proper contact.
●
Under-Voltage Recovery Timeout(15 minutes)
●
Excessive power supply voltage
●
Thermistors short to ground
Battery in rapid charge mode.
Battery is charged to 90 % or greater capacity.
Battery is fully charged.
No battery in pocket.
What to do...
●
Check that the RSM with battery, or the battery
alone, is inserted correctly.
●
Make sure that the power cord is securely plug-
ged into the charger and an appropriate AC
outlet, and that there is power to the outlet.