Please note that depending on the chosen settings and loading, it takes approximately
24 hours for the wine cellar to reach the desired temperature.
▪ Control panel
1. On/Off: press the button for 5 seconds to turn the cellar on or off.
2. Screen lock: press the icon for 3 seconds, the symbol will appear on the screen
when the control panel is locked. Perform the same operation to unlock the screen.
This button also allows the display of the actual temperature, the screen displays
the set temperature. Press the symbol to view the measured temperature.
3. The lighting is triggered manually by pressing the button. To turn it off, press
this icon again.
4. Button to increase the set temperature by 1°C
5. Button to decrease the set temperature by 1°C
6. Temperature Setting: Press the button to begin temperature settings. Press the
"up" and "down" arrows to set the desired temperature. The factory default setting
is 12°C. Press the button again to confirm your choice.
3+6. Active carbon filter wear alarm (change every year): press the SET button
and the light button at the same time to display the time remaining in the carbon
filter, the screen shows the time usage successively the number of days, hours
and minutes, each will be displayed for 5 seconds. When you change the carbon
filter, the countdown and alarm will not reset automatically. You need to press the
SET button and the light button for 3 seconds.
4+5. Display in Celsius or Fahrenheit: press the up and down arrows
simultaneously for 3 seconds to switch from one to the other.
NB: when you set a new setting, it is normal that the cellar does not immediately
reach the requested temperature. It is also normal to have +/- 2°C difference
between the set temperature and the temperature recorded.
NB: The temperature and/or humidity alarm may be triggered as soon as your
device is switched on. This is normal because without having operated, the cellar
may measure abnormal temperature or humidity values (outside the 40-80% and
5-20 degree ranges). You can turn off the sound alarm by pressing any button.