Télécharger Imprimer la page

Peavey IPR2 5000 Mode D'emploi page 30

Publicité

Crossover Filters, Band-Pass Filters and Polarity
Set: BP Filters Independently
When you enter the "XOVER" Sub Menu, you are given three
options for how the band-pass filters can be set. When Set "BP
Filters Independently" is selected, the Channel A and B high-
pass and low-pass filters are individually set.
Set: BP Filters Channel B=a
If you are using the amplifier in a stereo system where both
channels will be set the same, select "Channel B=A" and both
channels will be set at once. Setting the filters for Channel A
also sets Channel B.
Set: X-Over Freq a Lows B Highs
If you create a crossover between channels of the amplifier,
select "X-over Freq A Lows B Highs" and crossover frequency
and filter type can be set with one set of controls. Set by
crossover screen, High-pass and Low-pass screens.
The filter types available for the high-pass and low-pass filters are:
Off
No filter
BW-12 dB
Butterworth filter with 12 dB per octave slope. -3dB at corner frequency.
Butterworth filters have a flat frequency response in the pass-band.
BW-18 dB
Butterworth filter with 18 dB per octave slope. -3dB at corner frequency.
Butterworth filters have a flat frequency response in the pass-band.
BW-24 dB
Butterworth filter with 24 dB per octave slope. -3dB at corner frequency.
Butterworth filters have a flat frequency response in the pass-band.
LR-24 dB
Linkwitz-Riley Filter with 24 dB per octave slope. -6dB at corner frequency.
LR filters combine for a flat response at the corner frequency.
It is generally a good idea to use a high-pass filter for all loudspeakers.
Unlike the other function Sub Menus, the input mode does not
change until you select "Save and Apply" and return to the
Main Menu.
30

Publicité

loading

Ce manuel est également adapté pour:

Ipr2 7500Ipr2 5000 dspIpr2 7500 dsp