Connect the cable to the indoor unit (for SC 13xx models)
1.
4.5 Meter cable for electrical connection between indoor and outdoor unit is delivered with the pac-
kage and is included in the refrigerant piping sleeve.
2.
The electrical cable is provided with an electrical quick connector (see figure 21).
3.
The outdoor unit is also provided with electrical quick connector (see figure 22).
4.
Connect the electrical quick connectors.
Connect the green/yellow earthing wire separately to the connection spot marked with
Fig. 21
Connect the cable to the indoor unit (for S 13xx models)
1.
Indoor/Outdoor connection cable should be H07RN-F type.
2.
Remove the panel and screw, then remove the window cover. (fig. 23)
3.
Connect cables according to their marks to terminals. (fig. 24)
4.
Wrap those cables not connected with terminals with insulation tapes, so that they will not touch any
electrical components.
5.
Fit the power cord clamp.
4
76
11:41
Pagina 76
All manuals and user guides at all-guides.com
Fig. 22
Terminal block of indoor unit
L
N
S
Cord clamp
To outdoor unit
<3.0 kW
Fig. 23
L
N
S
To outdoor unit
≥ 3.0 kW
Fig. 24
.