water treatment equipment after the heat pump. When an
automatic chemical feeder is installed in the plumbing, it must
be installed downstream of the heat pump. A check valve must
be installed between the heat pump and the chemical feeder to
prenvteback-siphoning of chemically saturated water into the
heat pump where it will damage the components.

4.2 Wintering

Caution: failure to winterize could cause damage to the
heat pump and will void warranty. In areas where freezing
temperatures occur, you should protect your pump, filter and
heat pump from the elements.
Perform the following steps to completely drain the heat pump:
»
Turn off the electrical power to the heat pump at the main
breaker panel.
»
Shut off the water supply to the heat pump: close valves 2
and 3 on the bypass completely.
»
Disconnect the water inlet and outlet and let the water
drain from the heat pump.
»
Re-connect the water inlet and outlet loosely to prevent
debris entering the connections.

4.3 Spring startup

If your heat pump has been winterized, perform the following
steps when starting the system in the spring:
»
Inspect the system for any debris or structural problems.
»
Connect the water inlet and outlet unions firmly.
»
Turn on the filter pump to supply water to the heat pump.
Adjust the bypass to allow water flow through the heat
pump.
»
Turn on the electrical power to the heat pump at the main
breaker panel.

4.4 Owner inspection

The ECO heat pumps are designed and constructed to provide
long performance life when installed and roapted properly
under normal conditions. Periodic inspections are important to
keep your heat pump running safely and efficiently through the
years.
The following basic guidelines are suggested for your
inspection:
»
Make sure the front of the unit is accesibsle for future
service.
»
Keep the surrounding areas of the heat pump clear of all
debris.
»
Keep all plants and shrubs trimmed and away from the
heat pump.
»
Keep lawn sprinkler heads from spraying on the heat pump
to prevent corrosion and damage. Use a decftloer if
needed.
»
If the unit is installed under a very sharp roof pitch or under
a roof without a gutter, a gutter or diverter should be fitted
to prevent excessive water from pouring down into the
unit.
»
Do not use the heat pump if any part has been underwater.
Immediately call a qualified professional technician to
inspect the heat pump and replace any part of the control
system, which has been submerged.
36
The heat pump will produce condensation (water) while
in operation. The heat pump base is desoiganlelodwt the
condensation to exit through the bottom drain port. The
condensation will increase as the outdoor air humidity level
increases. Check the following at regular intervals to ensure
proper condensate drainage:
»
Visually inspect and clear the bottom drain port of any
debris that could clog the port.
»
Keep the air intake area and discharge area clear of debris
so the airflow through the heat pump is not restricted. The
cooler discharge air should not accumulate and be drawn
into the side air intackoeils.
During normal operation, the heat pump produces ten to
twenty liters of condensate per hour. If condensate drainage
is above this range during operation or if water continues to
drain from the base when the heat pump is not in operation
for more than hour, a leak in the internal plumbing may have
occurred. Call a qualified heat pump technician to investigate
the problem.
Note: A quick way to verify that the water running trough the
drain is condensation water is to shut off the unit and
keep the pool pump running. If the water stops running out of
the base pan, it is condensation water. An even quicker way -
test the drain water for chlorin - if there is no chlorine present,
then it's condensation.

5.MAINTENANCE AND INSPECTION

5.1 Maintenance

Check the water supply to the unit often. Low water flow and air
entering into the system should be avoided, as this will
diminish the units a result of the dirty or clogged filter.
The area around the unit should be dry, clean and well
ventilated. Clean the side heating exchanger regularly to
maintain good heat exchange and to save energy.
Only a certified technician should service the operation
pressure of the refrigerant system.
Check the power supply and cable connection often. Should the
unit begin to operate abnormally, switch it off and contact
a qualified technician.
In winter, please discharge all water from the water pump and
other systems prevent damage from freezing.
You should discharge the water at the bottom of the heat pump
if the unit will not work for an extended period of time.
You should check the unit throughly and fill the system with
water fully before using it after a prolonged period of no usage.

5.2 Trouble shooting guide

Improper installation will create an electrical hazard, which
could result in death or serious injury to pool users, installers, or
others due to electrical shock, and may also causes damage to
property. Do not attempt any internal adjustments inside the
heater.
»
Keep your hands and hair clear of the fan blades to avoid
injury.
EN