3.INSTALLATION OF THE HEAT PUMP UNIT

3.1 Installation items:

The factory only provides the heat pump unit; the other items
including an eventual bypass, in the illustration are necessary
parts for the water system, provided by users or the installer.
Attention:
Please follow these steps when installing the heat pump:
»
All feeding of chemicals to the pool water has to be done
downstream of the heat pump.
»
Install a bypass when the flow of the pool pump is more
then 20% above the rated flow of the heat exchanger of
the heat pump.
»
Install the heat pump on a sodlifoundation and use the
damping rubbers to eliminate vibrations and noise.
»
Always keep the unit straight up. If the unit has been tilted
or put on his side, allow 24h before starting the unit.

3.2 Heat pump location

The unit may be installed virtualyl anywhere outdoors. For
indoor pools please consult your supplier.
Do not put the unit in an enclosed area with a limited air
volume where the unit discharge air will be r-ceirculated.
Do not put the unit next to shrubs, which can block the air
inlet. Schu locations deny a continuous source of fresh air, which
reduces its efficiency and may prevent adequate heat delivery.
The picture below give the minimum required distances from
each side of the heat pump.
Install the heat pump where you have the best access to warm
air during the swimming season.

3.3 How close to the pool?

Install the heat pump as close to the swimming pool as possible
to minimize the loss of heat through the piping.
Put it on a solid base and place the rubber blocks under the
heat pump to eliminate vibrations.
34

3.4 Check valve installation

Caution Placement of the chlonriator, water balance equipment,
and the placement of injectors of chemicals, are very important
aspects of the installation. All addition of chemicals have to be
done downstream from the heat pump. Failure to protect the
heat pump unit from chemical daemiasgnot covered under the
warranty.

3.5 Typical configuration

Note: the above piping connection is only an example for demon-
stration

3.6 Setting the bypass

With the bypass set correctly, your heat pump will deliver its
best performance. The bypass has to be built as show below:
TO
POOL
OUT
VALVE 1
Slightly closed (water pressure increased with just 100 to 200 gr)
EN
FROM
FILTER
IN

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

596952455969527859695295Eco-3Eco-5Eco-8 ... Afficher tout

Table des Matières