2. SPECIFICATIONS

2.1 Performance data of ECO Swimming Pool Heat Pump Unit

Unit
Heating Capacity
COP
Power Input
Maximum Pool
Volume
Running Current
Power Supply
Fuse current
Controller
Heating exchanger
Compressor Quantity
Compressor
Refrigerant
Fan quantity
Fan Power Input
Fan Speed
Fan Direction
Noise at 1m
Water Connection
Nominal Water Flow
Water Pressure Drop (max)
Unit Net Dimensions
Unit Shipping Dimensions
Net Weight / Shipping Weight
* Measurement conditions: Dry bulb: 24 °C, Wet bulb: 19 °C , water inlet temperature: 27 °C
32
Model
Eco-3
A24/W27
3200W
A15/W27
700W
A24/W27
4.6
A15/W27
4.5
W
600
12
A
3.0
V/Ph/Hz
220-240/1/50
A
10A
1
Rotary
R32
1
W
20
RPM
950
dB (A)
48
mm
50
m³/h
2-4
kPa
10
700/300/490
L/W/H mm
L/W/H mm
820/315/525
Kg
29/32
Eco-5
Eco-8
4500W
7800W
1000W
1650W
4.6
4.7
4.4
4.6
880
1300
18
30
4.4
7.5
220-240/1/50
220-240/1/50
10A
16A
Mechanical control
Titanium in PVC
1
1
Rotary
Rotary
R32
R32
1
1
25
25
900
900
Horizontal
48
48
50
50
3-5
4-7
10
12
700/300/490
936/360/550
820/315/525
1090/90/580
36/39
54/57
EN
Eco-10
9500W
2230W
4.9
4.5
1800
40
10
220-240/1/50
20A
1
Rotary
R32
1
30
890
48
50
4-7
15
1010/370/615
1170/415/645
63/67