INTRODUCTION
EN
This instruction sheet provides you with the information required to
safely own and operate your Little Giant pump. Retain these instruc-
tions for future reference.
The Little Giant pump you have purchased is of the highest quality
workmanship and material, and has been engineered to give you
long and reliable service. Little Giant pumps are carefully tested,
inspected, and packaged to ensure safe delivery and operation.
Please examine your pump carefully to ensure that no damage
occurred during shipment. If damage has occurred, please con-
tact the place of purchase. They will assist you in replacement or
repair, if required.
READ
THESE
INSTRUCTIONS
ATTEMPTING TO INSTALL, OPERATE, OR SERVICE YOUR
LITTLE GIANT PUMP. KNOW THE PUMP'S APPLICATION,
LIMITATIONS,
AND
POTENTIAL
YOURSELF AND OTHERS BY OBSERVING ALL SAFETY
INFORMATION.
FAILURE
INSTRUCTIONS COULD RESULT IN PERSONAL INJURY
AND/OR PROPERTY DAMAGE!
DESCRIPTION
Little Giant submersible effluent pumps are recommended for
use in basins or lift stations and are suitable for pumping sew-
age, effluent, wastewater and other non-explosive, non-corrosive
liquids with up to 3/4" spherical solids.
Automatic operation can be achieved with the use of the Remote
Float Switch (RFS). Other accessories such as basins, check
valves, and covers are also available.
Figure 1
8E-CIA-RFS
8E-CIM
9E-CIA-RFS
9E-CIM
Submersible Effluent Pump
Pompe Pour Effluent Submersible
Bomba Efluente Sumergible
CAREFULLY
BEFORE
HAZARDS.
PROTECT
TO
COMPLY
WITH
THESE
8E-CIA SERIES
SPECIFICATIONS
Discharge Size:
1-1/2" NPT vertical
Intake Size:
3/4" screened opening
Pump Housing:
Cast iron
Volute:
Cast iron
Screen:
ABS
Impeller:
Vortex design, with pressure relief vanes
Motor:
Single phase induction, 1750 RPM, with auto-
matic reset thermal overload protection
Hardware:
300 Series stainless steel
Thrust Bearing:
Double shielded ball
Radial Bearing:
Sleeve — permanent lubrication
Pump Shaft Seal: Mechanical, spring loaded, stationary carbon
with Nitrile boot and rotating ceramic seat
Power Cord:
16 AWG 3-conductor, copper, stranded
Cooling:
The motor housing contains oil to cool the
motor and to lubricate bearings and seals.
These pumps are capable of operating with the
motor housing partially exposed for extended
periods of time, providing sufficient motor cool-
ing and bearing lubrication. However, for the
best cooling and longest motor life, the liquid
level being pumped should normally be
above the top of the cast iron motor housing.
SAFETY GUIDELINES
WARNING: RISK OF ELECTRIC SHOCK. This pump is supplied
with a grounding conductor and grounding-type attachment plug.
To reduce the risk of electric shock, be certain that it is connected
only to a properly grounded, grounding-type receptacle.
Your 115V pump is equipped with a 3-prong electrical plug. The
third prong is to ground the pump to prevent possible electrical shock
hazard. Do not remove the third prong from the plug. A separate
branch circuit is recommended. Do not use an extension cord.
9E-CIA SERIES
1