For residential and light commercial use, the Model 8 Series sump pumps provide efficient and reliable
service. For extended or continuous use in moving large volumes of water, these pumps feature a 1-1/2"
discharge with a maximum head of 22.9', a polycarbonate cover and a polypropylene volute/base. A choice
of manual or automatic versions provides user with the right pump for their needs.
8 Series
Features
Cast bronze or cast iron pump housing with
n
Oil-filled motor housing for lifetime lubrication
n
4/10 HP shaded pole motor
n
Stainless steel fasteners
n
Mechanical seal (stainless steel spring, nitrile
n
Bearings: Upper and lower sintered sleeve
n
Thermal overload protection
n
Manual and automatic models
n
Automatic operation with pressure switch
n
Heavy Duty Power Cord
Oil-filled To Dissipate Heat
For Extended Pump Life
Automatic Operation
With Pressure Switch
Submersible Sump Pump
protective epoxy coating for corrosion resistance
and rapid heat dissipation
parts, carbon and ceramic faces) to assure
maximum protection against pump failure
bearings for extended motor life
activates pump when water level is between 7"
and 10". Pump shuts off when water level falls
to between 1" and 4" (pressure switch is non-
adjustable).
Stainless Steel Lifting Ring
8-CI A
Big John
Cast Bronze Housing or
Cast Iron
With Protective Epoxy Coating
To Resist Corrosion
Stainless Steel Screws
Motor Designed For
Maximum Performance
CRS
Non-Clog
Impeller
Engineered
To Enhance
Performance
& Reliability

Publicité

loading

Sommaire des Matières pour Little Giant 8 Serie

  • Page 1 Big John Submersible Sump Pump 8 Series Features Cast bronze or cast iron pump housing with protective epoxy coating for corrosion resistance Oil-filled motor housing for lifetime lubrication and rapid heat dissipation 4/10 HP shaded pole motor Stainless steel fasteners Mechanical seal (stainless steel spring, nitrile parts, carbon and ceramic faces) to assure maximum protection against pump failure Bearings: Upper and lower sintered sleeve bearings for extended motor life Thermal overload protection Manual and automatic models Automatic operation with pressure switch activates pump when water level is between 7" and 10". Pump shuts off when water level falls to between 1" and 4" (pressure switch is non- adjustable). Cast Bronze Housing or Cast Iron With Protective Epoxy Coating Heavy Duty Power Cord To Resist Corrosion Stainless Steel Lifting Ring Oil-filled To Dissipate Heat...
  • Page 2 22.9 21.30 6.00 x 9.50 x 8.50 Continuous Duty Rated — “Little Giant Wastewater pumps are rated continuous duty as long as they are run within the published ratings for these pumps.” CIM/CBM – Manual CIA/CBA – Automatic All models are 60 Hz.
  • Page 3 RISK OF ELECTRIC SHOCK—This pump is supplied with a 8-CIM, 8-CBM Little Giant grounding conductor and grounding-type attachment plug. To 6-CIA, 8-CIA, 8-CBA P . O. Box 12010 reduce the risk of electric shock, be certain that it is connected Oklahoma City, OK 73157-2010 only to a properly grounded, grounding-type receptacle.
  • Page 4 Figure 2. 6. TEST THE PUMP AFTER ALL CONNECTIONS HAVE BEEN 4. In situations where the piping is long, vertical discharge is MADE. Run water into sump. Do not attempt to operate the above 7 or 8 feet, or a small pit has been provided, use of a pump without water;...
  • Page 5 CONNEXIONS ÉLECTRIQUES (FIGURE 1) F DIRECTIVES DE SÉCURITÉ La pompe est équipée d’une prise électrique à trois broches. Pour éviter les risques d’électrocution, la troisiéme broche relie la Bien lire les instructions du Guide de sécurité. Le non-respect des pompe à la terre. Ne pas retirer la troisiéme broche de la prise. Un consignes de sécurité...
  • Page 6 CONEXIONES ELECTRICAS (FIGURA 1) E NORMAS DE SEGURIDAD Su bomba está dotada de un enchufe eléctrico de tres dientes. El tercer diente es para ponderla a tierra, con el fin de evitar el riesgo LEA TODO EL INSTRUCTIVO, EL NO SEGUIR ESTAS de posibles choques eléctricos.
  • Page 7 Figure 3. MANUAL AUTOMATIC REPLACEMENT PARTS LIST PUMPS PUMPS Item Part Description 8-CIM 8-CBM 6-CIA 8-CIA 8-CBA 108101 Handle, Pump • • • • • 928004 Seal Ring • • • • • 108034 Pump Base • 108033 Pump Base •...
  • Page 8 TROUBLESHOOTING INFORMATION • INFORMATION SUR LA RELÈVE DES DÉRANGEMENTS • INFORMACION DE INVESTIGACION DE AVERIAS PROBLEM • FONCTIONNEMENT DÉFECTEUX PROBABLE CAUSES • CAUSES PROBABLES CORRECTIVE ACTIONS • SOLUTIONS • SOLUCION • PROBLEMA • CAUSAS PROBABLES •Pump will not shut off. NOTE: Before troubleshooting Diaphragm switch •...
  • Page 9 à sa sortie de l’usine. La pompe est garantie contre tout at the option of Little Giant as the sole remedy of buyer. For défaut de matériau ou de fabrication pendant une période de 12 our customers in the CONTINENTAL UNITED STATES: Please mois (90 jours pour les Modèles: 1-AA-OM, GKPK-SC, PP-1,...