6.2
Position of transmitter and receiver
The recommended installation height for transmitter and receiver is between 0.70 m
and 1 m. Both components can be adjusted horizontally (+/-90° ) and vertically (+/-
15° ). This permits flexible installation in the mos t varied physical conditions (see
examples A, B and C).
6.3
Detection range
When installing the photoelctric beams, note the detection range (L) and radiation
range (X) of the transmitter.
Model
Detection range L (Outdoors)
LS2030
30 m
LS2060
60 m
LS2080
80 m
LS2120
120 m
6.4
Wall mounting
14
Wandmontage1
Spread of beams X
0.9 m
1.8 m
2.4 m
3.6 m