Standby mode is deactivated as
soon as you operate the display or
open the door.
You can switch off the light bar in
standby mode.
Switching on the light bar
Press and hold
▶
3 seconds until an audible signal
sounds.
Switching off the light bar
Press and hold
▶
3 seconds until an audible signal
sounds.
4 Installation and con-
nection
4.1 Scope of delivery
After unpacking all parts, check for
any transport damage and for com-
pleteness of delivery.
If you have any complaints, contact
your dealer or our after-sales service
→ Page 31.
The delivery consists of the following:
¡ Free-standing appliance
¡ Equipment and accessories
¡ Installation instructions
¡ User manual
¡ Customer service directory
¡ Warranty enclosure
¡ Energy label
¡ Information on energy consump-
tion and noises
1
Depending on the appliance specifications
2
Not in all countries
+
for
+
for
1
2
Installation and connection en
4.2 Criteria for the installation
location
WARNING
Risk of explosion!
If the appliance is in a space that is
too small, a leak in the refrigeration
circuit may result in a flammable mix-
ture of gas and air.
Only install the appliance in a
▶
space with a volume of at least
3
1 m
per 8 g refrigerant. The
volume of refrigerant is indicated
on the rating plate. → Fig.
The weight of the appliance ex works
may be up to 115 kg depending on
the model.
The subfloor must be sufficiently
stable to bear the weight of the appli-
ance.
Permitted room temperature
The permitted room temperature de-
pends on the appliance's climate
class.
The climate class can be found on
the rating plate. → Fig.
Climate
Permitted room tem-
class
perature
SN
10 °C to 32 °C
N
16 °C to 32 °C
ST
16 °C to 38 °C
T
16 °C to 43 °C
The appliance is fully functional within
the permitted room temperature.
If an appliance with climate class SN
is operated at colder room temperat-
ures, the appliance will not be dam-
aged up to a room temperature of
5 °C.
/
1