MOUNTING INSTRUCTIONS
WALL MOUNTING
1) Determine the location to mount the enclosure. Use the following considerations in selecting a mounting location:
a) Appropriate mounting base per applicable codes and Authority Having Jurisdiction (AHJ).
b) Space around the enclosure to open the door and route patch cables. Additional space consideration is
required to open the door when stacking enclosures.
c) Adequate space above or below the enclosure to maintain industry standard bend radius compliance of all
cables entering the enclosure.
2) Using a level, place the enclosure at the target mounting location and mark the four mounting hole positions.
4) Install the bottom two screws.
DIN RAIL MOUNTING
Follow instructions provided with the DIN Rail Mounting Kit (DNRAL-ACC).
ZERO RU MOUNTING
RACK OR CABINET RAIL INSTALLATION (with Zero RU Mounting Bracket Kit #5WMNB-ACC)
1) Determine target location for mounting.
2) Determine inward or outward mounting bracket orientation.
3) Using #12-24 (or other appropriately sized) rack mounting screws, attach (1) mounting bracket to rack rail. (Figure 1).
4) Using provided #8 screws and washers provided in the mounting bracket kit, secure enclosure base to bracket. (Figure 2)
Figure 1
RACK OR CABINET RAIL INSTALLATION (with Set of 4 Magnet Kit #41030-SMJ)
1) Determine target location for mounting.
2) Attach double sided tape to each of the 4 magnets.
3) Attach the magnet assemblies to the locations as shown in Figure 3
DI-000-5WMNT-20C
Figure 2
.
Page 5 of 30