Potential scald or thermal shock injury could result due to cross flow if outlet at the shower is
blocked or restricted (e.g., pause control on showerhead). Be sure to point showerhead away
from you when re-starting flow or install inlet check valves on both supply lines to prevent
possible injury.
Faucet leaks from showerhead:
SHUT OFF WATER SUPPLIES. Replace Cartridge
Assembly –Repair Kit RP46074.
75P Series Installation
75P Series Maintenance
If water does not flow:
Verify that the hot side of the cartridge is installed
on the hot water supply line. If it is not, turn off
water supplies and flip cartridge.