Plamen 850 Glas residential cookers fired by solid fuel are only a small part of our
assortment of Plamen cookers which can completely satisfy your needs. In order to achieve the
best performance of the cookers, please READ THESE INSTRUCTIONS CAREFULLY.
The appearance of the cooker is shown on the cover page. The basic parts are made of
enamelled and galvanized steel sheet and of high quality cast iron. The cookers with a right and
left side flue connection are both available. This should be specified when ordering the entire
appliance or spare parts thereof. A right side flue connection cooker is the one which has the
connection on the right viewed from the front side of the cooker and vice versa in terms of left
side flue connection cookers.
Technical Data
Measurements: W x H x L
Weight:
Nominal output:
Flue connection (top and rear):
Required negative pressure in the chimney:
Flue gas flow at the above nominal output:
Recommended fuel loads regarding
the above nominal output:
-wood
Optimum log size:
-perimeter
-length
Installation Instructions
When installing the cooker, make sure that relevant local, national and European
regulations are fully observed.
After having unpacked the cooker, inspect it carefully for possible damages in transport.
Any such damages should be immediately reported, because late claims will not be taken
into consideration.
In the log drawer, you will find a handrail and accessories, which should be fixed to the top
frame as shown in Figure 1.
Install the flue collar in its position making sure that the connection between the
cookstove and chimney is firm and tight. The cooker is connected to the chimney with a
standard flue pipe dia. 120 mm.
The flue pipes should have adequate rise at all places. Do not connect the cooker to a
chimney to which another appliance has already been connected. Make sure that the chimney
is free from any cracks and damages.
The cooker should be installed in a room with sufficient fresh air to support the
combustion. If an exhauster (hood) or similar air-consuming unit is installed in the same room,
regular inflow of fresh air should be provided through a separate opening, protected with a non-
clogging grid.
84,5x83,8x59,4 cm
121 kg
8 kW
Ø 120 mm
10-20 Pa
7,7 gr/sek
2 - 3 kg/h
20-30 cm
25-35 cm