Télécharger Imprimer la page

Schneider Airsystems UNM 510-10-90 DX Notice D'utilisation D'origine page 33

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 35
Problem
C
Compressor
not
start
when
switched on.
D
The
compressor
starts
up
briefly
when the switch-on
pressure is reached
or
hums,
switches off auto-
matically.
E
Compressor
continuously.
F
During
operation,
compressed
escapes
via
load-relieving valve.
G
After the switch-off
pressure is reached,
compressed
escapes
via
load-relieving valve
until
switch-on
pressure is reached
H
Compressor
switches
on
quently.
I
Safety valve blows
out.
Cause
does
Vessel pressure is higher than
switch-on pressure.
Power supply faulty.
Protective motor switch inter-
rupts power supply.
Pressure switch defective
Mains connection cable longer
than permitted or the cross
section is too small.
then
runs
Intake filter badly contami-
nated.
Air consumption of compressed
air tools is too high.
Leakage at compressor.
Excessive condensate in the
vessel.
Compressed air line leaky:
Condensate drain valve is open
or missing.
Load-relieving valve leaky.
air
the
Check valve insert leaky or
defective.
air
Check valve is damaged.
the
Excessive condensate in the
fre-
pressure vessel.
Compressor overloaded.
Vessel pressure is higher than
the set switch-off pressure.
Safety valve is defective.
Remedy
Relieve pressure in the vessel
until the pressure switch is acti-
vated automatically.
Have the power supply checked
by a qualified person (service
partner).
See item A.
Have
the
pressure
changed by a qualified person.
Check connection cable length
and
cable
cross-section
Chap. 2.4.4)
Clean or replace intake filter.
Check the air consumption of the
tools. Contact the service partner
Locate leak, contact service part-
ner.
Drain
the
condensate
Chap. 2.6.5).
Check compressed air line, plug
leak.
Close or replace.
Clean or replace load-relieving
valve.
Clean or replace the check valve
insert (see Chap. 2.6.11).
Replace check valve.
Drain
the
condensate
Chap. 2.6.5).
See item E
Have the pressure switch reset/
replaced by a qualified person.
Replace safety valve or contact
service partner.
GB
UNM
switch
(see
(see
(see
II/15

Publicité

loading

Ce manuel est également adapté pour:

A 714 001