Télécharger Imprimer la page

nVent RAYCHEM WinterGard Mesh Manuel D'installation Et D'utilisation page 11

Fonte de neige de surface

Publicité

Les langues disponibles

Les langues disponibles

Installation Overviews
Installation in concrete or asphalt
Finished concrete
or asphalt
Installation under pavers
Max. 2.5"
Sand bed / cement /
sand mixture
For installation under pavers (stone or brick), ensure that there is a solid base of 4" to 8" (102 mm to 203 mm) of crushed rock aggregate base and that it is tamped down and
prepared for the mortar pour. The sand or concrete layer directly above WinterGard Mesh should be hand tamped only.
IMPORTANT: Do not use sand for sloping areas since the sand will be washed away, resulting in damage to the heating wire.
Installation under asphalt
2.5"
Concrete slab
WARNING: Do not use any heavy equipment, machinery, or vehicles on top of an exposed WinterGard Mesh system.
WARNING: If the heating element needs to be loosened from the mesh to achieve good coverage, the installer should use spacers
to keep the heating element spacing consistent.
3"
WinterGard
Mesh
Concrete/compacted
substrate
3"
WinterGard
Mesh
Soil ground
WinterGard
3"
Mesh
Concrete / compacted
substrate
Temperature and
moisture sensor
Soil
Temperature and
moisture sensor
Stones / paver
Asphalt layer
Temperature and
1.22"
moisture sensor
Soil
2.5"
1" to1.5"
0.75"
|
nVent.com/RAYCHEM