3.4 WinterGard Mesh Installation
All connections and electrical testing should be carried out by a qualified electrician.
For irregularly shaped areas, it is acceptable to cut the mesh and adjust the heating element position in order to achieve good coverage.
See illustrative examples on page 13.
The heating element must not be cut or damaged
The heating element must not be crossed over itself
The heating element must not be installed within 3" (7.6cm) of another section of heating element or 1" from the cold leads
WinterGard Mesh must not be installed across expansion joints, across separate concrete slabs. Crack control joints may be crossed as
shown in the figure.
1/2 x 1/2 x 12 in
(1.2 x 1.2 x 30 cm)
angle iron filled
with RTV or silicone
rubber caulk
Angle iron
Minimum wire spacing is 3" (7.6cm)
Maximum exposure temperature for WinterGard Mesh: 221°F (105°C) (for asphalt pouring, short term exposure up to 464°F (240°C) is
allowed).
Base slab
The mesh must be secured to the underlaying surface to prevent movement during the installation. The cold lead cable must be protected
Well-drained base
in a conduit. The entire length of heating wire should be covered by wet sand-cement mixture, concrete, limestone screening, dry sand, or
Nonmetallic
asphalt depending on the selected top surface.
conduit
|
10
nVent.com/RAYCHEM
Voltage (V)
Width (ft)
120
2
120
2
120
2
120
2
120
2
120
2
120
3
120
3
120
3
240
2
240
2
240
2
240
2
240
2
240
2
240
2
240
2
240
2
240
2
240
2
240
3
240
3
240
3
240
3
240
3
Heating cable
Control joints
(cut into both bottom
and top slabs for two
pour installations)
Hot/cold joints
Cold leads
Length (ft)
Area (ft
)
2
5
10
10
20
15
30
20
40
25
50
30
60
10
30
15
45
20
60
5
10
10
20
15
30
20
40
25
50
30
60
35
70
40
80
45
90
50
100
60
120
10
30
20
60
25
75
30
90
40
120
Resistance (Ω)
Power (W)
28.8
500
14.4
1000
9.6
1500
7.2
2000
5.8
2500
4.8
3000
9.6
1500
6.4
2250
4.8
3000
115.2
500
57.6
1000
38.4
1500
28.8
2000
23.0
2500
19.2
3000
16.5
3500
14.4
4000
12.8
4500
11.5
5000
9.6
6000
38.4
1500
19.2
3000
15.4
3750
12.8
4500
9.6
6000