KanUK OrIGInal imPortant information
KanUK OrIGInal
IMPOrtant InFOrMatIOn
Installation site
Keep the following distances from combustible materials, otherwise there is a risk of fire.
EN
Kanuk® Original
7 kW / 9,5 kW
10 kW / 13 kW
15 kW / 18 kW
22 kW / 26 kW
* sp = side plate
Errors, misprints and technical changes reserved.
Combustible floor coverings must be fully protected by fire-
proof material. In addition, this material must be laid at least 50
cm to the front and at least 25 cm to the side of the firing cham-
ber. Make sure that the substrate has a load-bearing capacity
suitable for the furnace and, if applicable, the base frame.
note: Be aware that the stove and the mounted heat protection plates (optional) become hot during start-up,
posing a risk of burns. Do not touch the viewing pane and outer surfaces during operation!
Combustion air supply
For Kanuk® Original stoves, the combustion air supply is sufficient if the room where the stove is installed has at least
one door to the outside or a window. The window/door should be able to be opened and have a cross-section of at
least 150 cm². The installation room should have a volume of at least 4 m³ per kW of nominal heat output. When the
furnace is not in use, the primary and secondary air damper can be closed.
Ventilation requirements for simultaneous operation with other fireplaces
Oxygen or air is permanently required for the combustion process. As a rule, the air available in the installation
room is sufficient. In the case of well-sealed windows and doors, the presence of mechanical vents (e.g. kitchen or
bathroom) or other fireplaces (including
gas boilers) in the home, the proper air
supply can be severely disrupted. If this is
the case, it is possible to supply the com-
bustion air directly from the outside or
from another sufficiently ventilated room
(e.g. cellar). For this purpose, Kanuk® Ori-
ginal stoves have a combustion air spigot
on the back of the appliance, which can
be used to supply primary air, but is not
DiBt tested.
106
lateral with
forward
sp*
80 cm
25 cm
80 cm
35 cm
80 cm
45 cm
110 cm
40 cm
Combustion air spigot Kanuk® Original 7 kW, 9,5
Kanuk GmbH • Obercunnersdorfer Str. 4 • 01774 Klingenberg
lateral wit-
backward
hout sp*
52 cm
25 cm
60 cm
25 cm
75 cm
25 cm
80 cm
40 cm
kW, 10 kW, 13 kW, 15 kW & 18 kW
To the
upwards
ground
25 cm
75 cm
25 cm
75 cm
25 cm
75 cm
40 cm
75 cm
Combustion air spigot
Kanuk® Original 22 kW & 26 kW