17
7. Ignition test requires that the burner can be lit in 5 seconds normally, after 1
minute the flame is stable, there should be no liftedflame and yellow fire.
8. Similarly, when use in NG status, turn the marked NG arrow upwards and
tighten it to the screw cap(Fig.21). Repeat the above operation. The outlet
pressure requires to be 4 ± 1 in w.c.
9. After the conversion is completed, the conversion label in the accessory bag
needs to be attached next to the original la bel.
1#: Wok burner(Injector: NG-ø1.80mm/Propane-1.18mm)
2#: Rapid burner(Injector: NG-ø1.52mm/Propane-0.93mm)
3#: Semi-rapid burner(Injector: NG-ø1.26mm/Propane-0.79mm)
4#: Auxiliary burner(Injector: NG-ø0.94mm/Propane-0.62mm)
1 (844) 538-7890
support@gaslandchef.com
Incorrect flame:
lifting off the burner
Fig.22 (Incorrect and good flame patterns)
Original
Conversion
label
label
Good flame:
well-defined blue flame
with slight yellow tipping
(Product bottom)
Injector dimameter:
Fig.23
www.gaslandchef.com
8350 Patriot Blvd STE B, N. Charleston, SC 29418
1.80mm