Operation
Bit bracket
Insert the desired bit in the bracket designed
for this purpose (see figure, point 3). An
integrated magnet prevents the bit from
falling out.In view of the technical design, we
recommend that you only use small bits.
Changing the batteries
Insert a screwdriver in to the notch (2) and pry the battery compartment cover off. Make sure you
insert the batteries the right way round!
Only commission instruments that are closed!
Do not dispose of batteries in normal household rubbish! Use an authorised local
collection point!
Technical data
Voltage range
Power supply
Degree of protection
Overvoltage category
Testing standard
14
12 - 1000 V AC
2 x 1.5 V AAA Micro
IP 40
CAT III 1000 V / CAT IV 600 V
IEC/EN 61010-1 (DIN VDE 0411)
®