Télécharger Imprimer la page

Broan Elite SV05861 Instructions D'installation page 13

Publicité

Les langues disponibles

Les langues disponibles

21. USE AND CARE
Avoid: when choosing a detergent
- Any cleaners that contain bleach will attack stainless steel.
- Any products containing : chloride, fluoride, iodide, bromide will deteriorate surfaces rapidly.
- Any combustible products used for cleaning such as acetone, alcohol, ether, benzol, etc., are highly explosive
and should never be used close to a range.
22. OPERATION
Always turn your blower on before you begin cooking to establish an air flow in the kitchen. Let the blower run for a few
minutes to clear the air after you turn off the range. This will help keep the whole kitchen cleaner and brighter.
HC0007
1) ON/OFF blower switch
BLOWER
The blower is operated using two (2) controls or with the RMIPWC optional wall control.
Use the red, lighted on/off switch to start and stop the blower. When turned on, the blower will operate at the previous
setting of the speed control.
Turn the speed control knob clockwise to decrease blower speed - counterclockwise to increase speed.
COOKTOP LIGHTING (HALOGEN)
A double set of ON/OFF switches controls the halogen lights.
The fron rocker controls the center light (for 45'' inserts).The rear rocker controls both side lights (each switch controls
one light for 33'' insert). Select one, two or three lights for best cooking lighting.
Use PAR 20, 50 W halogen bulbs (purchase separately).
HEAT SENTRY™
This unit is equipped with a Heat Sentry thermostat. This thermostat is a device that will turn on or speed up the blower
if it senses excessive heat above the cooking surface.
1) If blower is OFF - it turns blower ON to HIGH speed.
2) If blower is ON at a lower speed setting – it turns the blower up to HIGH speed.
The HEAT SENTRY can start the blower even if the insert is turned OFF. In this case, it is impossible to
turn the blower OFF with blower switch. If you must stop the blower, do it from the main
electrical panel.
When the temperature level drops to normal, the blower will return to its original setting.
Test all insert switches. If a RMIPWC remote control is installed, test all its switches.
Finalize the custom hood.
RMIPWC REMOTE CONTROL (OPTIONAL)
An optional remote control is also available to operate your hood insert.
For installation details, see installation instructions included with the
RMIPWC remote control.
NOTE : When the RMIPWC remote control is connected to the insert,
the control switches on the insert are no longer operational.
(CONT'D)
2) Blower speed control
WARNING
!
- 13 -
2
1
3
3) Halogen light switches
1 2
HC0006
1) Light switch
3) Blower speed control
2) Blower ON/OFF switch
3

Publicité

loading

Ce manuel est également adapté pour:

Rmip45Rmip33