In the event of serious operating problem, stop using the fixture immediately. Never try
to repair the fixture by yourself. Repairs carried out by unskilled people can lead to
damage or malfunction. Please contact the nearest authorized technical assistance
center. There are no user serviceable parts inside the fixture except the fuse.
Do not connect the device to any dimmer pack.
To prevent or reduce the risk of electrical shock or fire, do not expose the fixture to rain
or moisture.
Do not look directly at the LASER light beam while the fixture is on.
Do not touch any wire during operation .
The unit should be mounted via its screw holes on the bracket. Always ensure that the
unit is firmly fixed to avoid vibration and slipping while operating. Always ensure that the
structure to which you are attaching the unit is secure and is able to support a weight of
10 times of the unit's weight. Also always use a safety cable that can hold 12 times of the
weight of the unit when installing the fixture.
The equipment must be fixed by professionals. And it must be fixed at a place where is
out of the touch of people and has no one pass by or under it.
Operating Premises: Whenever possible, the operation of a LASER should be done in a
room or in an enclosed or delimited place for this purpose.
The access of room and openings to the outside must not be located in the axis of a
direct beam.
The floor must be free of obstacles. The causes of accidental reflection and scattering of
laser beams must be removed (misplaced windows, furniture or objects with polished
faces).
The paintings (walls, partitions, ceilings ...) and flooring should preferably be matt. The
diffuse reflections of class 4 lasers, focused beams of lasers of class 3 to visible or near
infrared light should be considered dangerous and treated as such.
When using powerful lasers (Classes 3 to focused beam or 4), eliminate the beam
potential impact on flammable materials (wood, paper, fabric or plastic) that can be in
from fire in power densities of the order of several W.cm-2 applied for a few seconds.
7