Télécharger Imprimer la page

Bosch NEM5666UC Manuel D'installation page 7

Masquer les pouces Voir aussi pour NEM5666UC:

Publicité

Les langues disponibles

Les langues disponibles

Electrical Installation
Electrical requirements
You can find the identification plate with the electrical
specifications on the underside of the appliance. The
junction box must be located within 3 feet of the cooktop
connection. It should be easily accessible for service
purposes.
Power supply
Model
240 V AC, 60 Hz
system: circuit
breaker
NETP666SUC 40 Amp
NETP066SUC 40 Amp
NET8666UC
40 Amp
NET8066UC
40 Amp
NET8666SUC 40 Amp
NET8066SUC 40 Amp
NEM5666UC
40 Amp
NEM5066UC
30 Amp
Connect Electrical Supply
9
The electrical power supply system should be a 1-phase,
3-wire system with ground connection. Install suitable
junction box (not furnished). An appropriately-sized, UL-
listed conduit connector must be used to correctly attach
the conduit to the junction box.
The branch-circuit breakers ampacity, the wire sizes and
the connections must conform to the requirements of the
National Electrical Code or Canadian Electrical Code and
all local codes and ordinances.
Attach flexible conduit to the junction box.
9
Connect the cooktop lead wires to the junction box
supply wires in proper phase:
black (L1) to black
red (L2) to red
208 V AC, 60 Hz
system: circuit
blank copper wire to ground
breaker
Check the Installation
40 Amp
40 Amp
9
40 Amp
30 Amp
40 Amp
30 Amp
40 Amp
Remove everything from the cooktop surface including
30 Amp
stickers. Clean cooktop surface with cooktop cleaning
cream.
Switch on the circuit breaker.
Verify that elements function properly.
WARNING
Before installing, turn off at the service panel. Lock
service panel to prevent power from being turned
on accidentally.
WARNING
To reduce the risk of electric shock and fire, do not
use a flexible power supply cord.
CAUTION
Before you plug in an electrical cord or turn on
power supply, make sure all controls are in the OFF
position.
7

Publicité

loading