20
the system over the winter, especially if there is a risk of frost.
Circulate (6-way valve only/994615) – the water circulates through the pool system
without running through the filter.
2h
4h
6h
Timer indicator
ON/OFF
ON/OFF
button
ON/OFF button : Start/stop the pump.
Timer-button: To adjust the time, the pump must be stopped with the ON/OFF button;
otherwise, the time cannot be adjusted.
There are two operation modes in control panel: Continuous mode and single cycle
mode.
Continuous mode
After turn on the pump, the default setting is 24 hours continuous operation (indi¬cator
light 24h flashing). To set the desired operation period, press the Timer button; the
indicator lights cycles among 2h, 4h, 6h, 8h, 10h, 12h, 16h, 24h. To start the cycle, press
the ON/OFF button, the pump starts running. When the time is over, it will stop for the
reminder of 24h to start again the next day at the same time.
For example, if you set the timer to 4h and press [ON] at 8:00, the pump will operate
for 4 hours and stop at 12:00, and the indicator light will stop flashing. The pump will
start again for 4 hours at 8:00 every days.
Single cycle mode:
When press and hold the Timer button more than 10 seconds, single cycle indicator
light will flash and switch to single cycle mode (When the timer indicator light flashes in
24h, single cycle indicator light did not work). To set the desired operation time, press
the Timer button; the indicator lights cycles among 2h, 4h, 6h, 8h, 10h, 12h, 16h, 24h.
In the single cycle mode, after pressing [ON], the pump will work for the time set and
then stop. It will not work again until the power supply is reconnected.
For example, if you set the timer to 4h in single cycle mode, the pump will stop
automatically after running for 4 hours and it will not start again until you cut off the
power and reconnect the power supply.
Timer
8h
10h 12h 16h 24h
Single cycle indicator
TIMES
Timer button
Troubleshooting
Warning: disconnect the pump from the power supply first before taking any action.
Problem
Cause
Pump with no action
No power available
Pump works audibly, but no
1.Air in system (pump/tank)
water is flowing
2.Hoses kinked, pump is taking
in air
3.Suction height too high,
incorrect suction hose
Low-flow rate
1.Suction/delivery height
exceeded
2.Valve/hose/filter dirty
Pump stops suddenly
Overheating has triggered the
thermal switch
Sand in pool water
Fresh sand in filter
More sand in water
Incorrect quartz sand used
Heightened pressure
1.Blockage
2.High contamination
21
Solution
Insert plug or check fuses if
necessary
1.Ventilate the pump as
described and if necessary also
the tank.
2.Check and, if necessary,
correct and seal straightened
connections. Possible hose leak
3.Adjust the position of the
pump Use vacuum-safe suction
hose
1.Adjust the position of the
pump/system
2.Check and clean if necessary
Use a vacuum-safe suction hose
-wait approx. 30 minutes
-use vacuum-safe suction hose
-check clogged pipes
This is normal when fresh
sand is being used. Proceed as
described. It will settle of its
own accord.
Sand too fine, purchase coarser
sand from a specialist dealer
1.Cleaning
2.Cleaning and rinsing