RISK OF INDOOR AIR
WARNING
POLLUTION!
The products described in this manual are
kerosene direct-fired, forced air heaters.
Kerosene forced air heaters are primarily
intended for use for temporary heating of
buildings under construction, alteration or repair.
Direct-fired means that all of the combustion
products of the heater enter the heated space.
This appliance is rated at 98% combustion
efficiency, but does produce small amounts of
carbon monoxide.
CARBON MONOXIDE POISONING
DANGER
MAY LEAD TO DEATH!
Carbon monoxide is toxic. Humans can tolerate
only small amounts of carbon monoxide and so
precautions should be taken to provide proper
ventilation. Failure to provide proper ventilation
in accordance with the instructions in this manual
can result in death.
People with breathing problems should consult a
physician before using this heater.
Early signs of carbon monoxide poisoning
resemble the flu. Symptoms of improper
ventilation / carbon monoxide poisoning are:
Headache • Dizziness • Nausea
Sore Throat
Burning of Nose and Eyes
•
If you experience any of these symptoms:
GET FRESH AIR AT ONCE! Have your heater
serviced and check for proper ventilation. Some
people are more affected by carbon monoxide
than others. These include: pregnant women,
those with heart or lung problems, anemia or those
under the influence of alcohol or at high altitudes.
Not For Indoor Use. Indoor use permitted only
for the temporary heating of buildings under
construction, alteration or repair!
Provide at least a three square foot (2,800 sq
cm) opening of outside air for every 100,000
Btu / Hr heater rating. Refer to "Ventilation" on
page 6 for further instructions.
© 2015, Pinnacle Products International, Inc.
NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR
WHILE CONNECTED TO A POWER SOURCE
Safety Information
Dry Mouth
•
2
WARNING
RISK OF ELECTRIC SHOCK!
ALWAYS use only the electrical power (voltage and
frequency) specified on the model plate of the heater.
ALWAYS use only three-prong, grounded outlet and
extension cord.
ALWAYS use only 14 AWG or better extension cord.
ALWAYS unplug the heater when not in use.
ALWAYS install the heater so that it is not directly
exposed to water spray, rain, dripping water, or wind.
RISK OF BURNS, FIRE AND
WARNING
EXPLOSION!
NEVER use fuels such as gasoline, benzine, paint
thinners or other oil compounds in this heater.
NEVER refill the heater's fuel tank while the
heater is operating or still hot. This heater is
EXTREMELY HOT while in operation.
NEVER block air inlet (rear) or air outlet (front).
NEVER use duct work in front or rear of heater.
NEVER move or handle heater while still hot.
NEVER transport heater with fuel in tank.
NEVER use with an external fuel tank.
CAUTION! HOT WHILE IN
WARNING
OPERATION. DO NOT TOUCH.
KEEP CHILDREN, ANIMALS, CLOTHING AND
COMBUSTIBLES AWAY FROM HEATER.
Keep all combustible materials away from this heater.
Minimum Clearance From Combustibles
HH-150T-DFV
Top
4 ft.
Sides
4 ft.
Front
8 ft.
ALWAYS locate heater on a stable and level surface.
If your heater is equipped with a thermostat,
once it is plugged in, it can start at anytime in
accordance with the thermostat setting.
Dual Fusion Forced Air Heater User's Manual
HH-220T-DFV
4 ft.
4 ft.
8 ft.