INSTALLATION MANUAL
GALEO 4.0 Bluetooth
4. Unlock time
TMGALEO (OPTIONAL)
IP64
IK10
Vibrations tests
-25°C to +70°C
2] NOTES & RECOMMENDATIONS
Cable :
The distance between the GALEO and the remote
electronic can not exceed more than 10 meters.
Make sure that the cable is not near by a high
voltage cables (ex: 230 V AC).
Recommended cable between the GALEO
and the remote electronic :
To expand the supplied 3 meter cable, select a 2
Recommended power supplies suitable
for the GALEO :
ADC335 (230V input) or BS60 (230V input).
5. Create
user sheet
REMOTE CONTROLLER (BOXCODE)
IP52
-25°C to +70°C
Consumption
(3 relay outputs activated and
keypad illuminated)
AC
DC
Mounting recommendations :
vandalism and to insure the best mounting.
Security advice :
For security advice reasons, there is no master
code in the factory setting (only 5 terms).
The 1 2 3 4 5 code is forbidden as a master code.
When selecting a master code and user code avoid
sequencial codes (example : 3 4 5 6 7).
Back EMF protection :
To secure the system from back electromagnetic
on the lock.
6. Open the door
with the button
12 V
24 V
166 mA
82 mA
195 mA
105 mA
cdvigroup.com
EN
48 V
-
54 mA
11