4
Mounting and installation
i
Notes
All the drawings dimensions are shown in mm.
4.1
Preparing the mounting and
installation
4.1.1
Delivery and installation on site
4.1.1.1
product unpack
► Remove the product from its box.
► Remove the protective fi lm from all parts of the product.
4.1.1.2
Check scope of delivery
► Please check the scope of delivery for completeness.
- 1 Electrical module
- 1 temperature sensor
- 1 accessories bag
- 1 bag of documents (1 operating and installation)
4.1.2
Observing distances and mounting
clearances
4.1.2.1
Product and connection dimensions
0020152773_06 Electric Back-up Heater 6kW Installation manual
MOUNTING AND INSTALLATION
140
87
50
4.1.2.2
Distance to infl ammable parts
► Make sure that no item that can easily catch fi re is in
direct contact with the components, which may reach a
temperature greater than 80°C.
► Make sure that there is a minimum distance of 200 mm
between items that can easily catch fi re and the hot
surfaces.
4.1.2.3
Mounting clearances
► Ensure the distances indicated on the diagram.
This will ensure that the connections to the water can be
accessed and inspected.
Additional clearances around the appliance may be
advantageous for its installation and maintenance.
20
20
mini.
mini.
i
Notes
* Clearance necessary for the installation or
maintenance of the appliance.
140
101
50
>600*
EN