LOW IDLE SWITCH
This generator is equipped with an LOW IDLE Switch (Fig. 1).
Engaging this switch allows the system to regulate the engine
speed and automatically adjust its fuel consumption to match the
required load. When the electrical load changes, the generator
engine will automatically speed up and slow down as needed.
This reduces fuel consumption and noise levels, while extending
runtime and engine's lifespan.
Keep this switch engaged ONLY when the power load requirement is LESS THAN 75% of the rated watts.
Do not engage the switch when the total load is more than 75% of the rated watts. The generator engine
must run at full speed to supply power for anything over 75% of the rated watts.
PARALLEL OPERATION
The parallel operation outlets (Fig. 2) allow you to connect two
AIPOWER generators to increase the total available electrical power.
The AIPOWER Parallel Operation Kit can be purchased. Follow the
instructions included with your parallel operation kit for proper
installation and operation.
CIRCUIT BREAKERS
The circuit breakers (Fig. 3) protect the individual AC and DC
circuits. The circuit breaker will activate when the outlets exceed.
When the circuit breaker activates, turn off and disconnect the
device from its respective outlet, and press the circuit breaker to
reset.
CONNECTING ELECTRICAL DEVICES
CAUTION:
Before connecting devices, become familiar with the markings on the control panel before
connecting electrical devices. The 120V AC receptacles are for connecting electrical devices that run on
120V, 60 Hz, single phase, AC current. DO NOT connect 50Hz or 3-phase loads to the generator.
Follow the steps below to properly connect your device(s) to the generator:
1. Before connecting electrical devices, allow the generator to run for a few minutes to stabilize the speed
and voltage output.
2. Select the device with the highest wattage, and make sure it is turned off. Plug the device into the genera-
tor and then turn the device on. Allow the engine to stabilize.
3. Repeat step 2 to plug in each additional device. DO NOT attempt to plug in or start multiple devices at the
same time.