12
A fault, what to do?
WARNING:
Attention!
Repairs must only be carried out by an authorised technician. Improper
repairs can lead to risk of serious injury to the user.
12.1
Faults that the customer can troubleshoot himself
Fault
Water flow-rate is too low.
A high water temperature is set,
but it is not reached.
The display is blank.
The water is not warm.
The temperature of the water leaving
the tap is higher than the set
temperature.
Lights up in the display.
If the fault could not be eliminated, please call customer service.
12.2
Faults that the customer service specialist should troubleshoot
Fault
Water flow-rate is too low despite
cleaning of filter using the water tap
or showerhead.
The display is blank despite fault-free
function of the mains electricity supply
fuses.
The display shows the error code "E..". There is a fault in the appliance.
12.3
Faults that are automatically remedied
Fault
The display shows "00,0°C".
13
Data Protection Notice
We, Bosch Thermotechnology Ltd., Cotswold Way,
Warndon, Worcester WR4 9SW, United Kingdom
process product and installation information,
technical and connection data, communication data,
product registration and client history data to provide
product functionality (art. 6 (1) sentence 1 (b)
GDPR), to fulfil our duty of product surveillance and for product safety
and security reasons (art. 6 (1) sentence 1 (f) GDPR), to safeguard our
rights in connection with warranty and product registration questions
(art. 6 (1) sentence 1 (f) GDPR) and to analyze the distribution of our
products and to provide individualized information and offers related to
the product (art. 6 (1) sentence 1 (f) GDPR). To provide services such as
sales and marketing services, contract management, payment handling,
programming, data hosting and hotline services we can commission and
transfer data to external service providers and/or Bosch affiliated
enterprises. In some cases, but only if appropriate data protection is
ensured, personal data might be transferred to recipients located
outside of the European Economic Area. Further information are
provided on request. You can contact our Data Protection Officer under:
6 720 876 029 (2020/01)
Cause
The filter in either the water tap or the showerhead
is clogged.
The continuous-flow heater is connected to
a thermostatically-controlled water tap.
The fuse in the fusebox has tripped/blown.
The supply temperature has reduced.
The
temperature
of
the
the continuous-flow heater is higher than the set
temperature (e. g. due to pre-warmed water supplied
from a solar water heater).
The power limit has been reached.
Cause
A filter in the appliance is clogged.
There is a fault in the appliance.
Cause
The air sensor in the appliance detects air in the water
and momentarily switches the heating element off.
If your appliance does not operate as required, it is often due to a very
minor problem. Please check whether you can remedy the fault yourself
by using the following guidelines. You will save yourself the costs of an
unnecessary visit by customer service personnel.
Solution
Remove the filter and either clean it or descale it.
Set the temperature on the continuous-flow heater
to "60 °C".
Check the fuse in the fusebox.
Reduce the water flow on the taps until the desired
water temperature is reached.
water
supplying
The thermostatic premixer in the domestic supply
must be set accordingly to lower temperatures.
Reduce the water flow at the tap or lower
the temperature setting on the appliance.
Solution
Get a servicing expert to clean the appliance.
Get a servicing expert to check the appliance.
Get a servicing expert to check the appliance.
Solution
After a few seconds, the continuous-flow heater
automatically goes back into operation.
Data Protection Officer, Information Security and Privacy (C/ISP),
Robert Bosch GmbH, Postfach 30 02 20, 70442 Stuttgart, GERMANY.
You have the right to object, on grounds relating to your particular
situation or where personal data are processed for direct marketing
purposes, at any time to processing of your personal data which is based