Télécharger Imprimer la page

GE GE10P08BA Serie Manuel D'utilisation page 5

Publicité

Les langues disponibles

Les langues disponibles

IMPORTANT SAFETY INFORMATION
READ ALL INSTRUCTIONS BEFORE USING THE APPLIANCE
SAFETY CONTROLS
The water heater is equipped with a combination
thermostat and high limit Energy-Cut-Off control (ECO)
that is located above the upper heating element in
contact with the tank surface. If for any reason the
water temperature becomes excessively high, the
high limit control (ECO) breaks the power circuit to
the heating element. Once the control opens, it must
be reset manually. Resetting of the high limit control
should be done by a qualified service technician.
CAUTION
The cause of the high temperature
condition must be investigated by a qualified
service technician and corrective action must be
taken before placing the water heater in service
again.
READ AND SAVE THESE INSTRUCTIONS
49-6000247 Rev. 1
To reset the temperature-limiting control:
1. Turn off the power to the water heater.
2. Remove the jacket access panel(s). The thermostat
protective cover should not be removed.
3. Press the red RESET button.
4. Replace the jacket access panel(s) before turning on
the power to the water heater.
5. Ensure water heater is operating properly after
resetting the ECO.
5

Publicité

loading

Ce manuel est également adapté pour:

Ge20p08ba serieGe20l08ba serieGe10p08barGe20p08bar