Télécharger Imprimer la page

Fulgor Milano F4IT24S2 Instructions D'installation page 12

Masquer les pouces Voir aussi pour F4IT24S2:

Publicité

Les langues disponibles

Les langues disponibles

5 - Electrical Connections
EN
DANGER
Disconnect power before servicing the product. Failure to do
so could result in death or electrical shock.
General information
WARNING
The models may be powered at 240V or 208V.
This cooktop does not require a neutral connection. If the cooktop
is to be completely enclosed in a cabinet, feed the cooktop
cable through the opening in the cabinet. Make the electrical
connection following the appropriate steps for your installation.
Your cooktop must be connected to the proper electrical voltage and
frequency as specified in the table on the right.
Location of serial tag
Connect with copper wire only
If the house has aluminum wiring, follow the procedure below:
1. Connect the aluminum wiring to the copper wire by using
special connectors designed and Underwriters Laboratories-
listed for joining copper to aluminum. Follow the electrical
connector manufacturer's recommended procedure.
2. Aluminum/copper connection must conform with local
codes and industry- accepted wiring practices.
The flexible conduit (supplied) 3 feet long (100 cm) located
at the right rear of the cooktop bottom box should be
connected directly into a junction box. Do not cut the
conduit. A U.L - or CSA - listed conduit connector must
be provided at each end of the power supply cable (at
the cooktop and at the junction box.) A time delay fuse or
circuit breaker is recommended. Do not ground to a gas
pipe. Do not have a fuse in the grounding or neutral circuit.
Fuse both supply (phase) lines.
10
WARNING
Improper connection of aluminum house wiring to the copper
leads can result in a serious problem such as an electrical
fire.
Model
Power Supply
240 V 60
Hz
24" F4IT24*2 7,2kW 30A 6,3kW 30A 817Y4**X
30" F4IT30*2 7,2kW 30A 6,3kW 30A 817T4**Y
National Fire Protection Association Battery-
march Park, Quincy, Massachusetts 02169-
7471
A three-wire, single phase, 240 Volt 60 cycle electrical system
(properly circuit protected to meet Local Codes of NFPA
No.70) must be provided. Unit must be properly grounded in
accordance with local wiring code.
Be sure your appliance is properly installed and
grounded by a qualified technician. Ask your
dealer to recommend a qualified technician or an
authorized repair service. This cooktop does not
require a neutral connection. If the cooktop is to be
completely enclosed in a cabinet, feed the cooktop
cable through the opening in the cabinet. Make
the electrical connection following the appropriate
steps for your installation.
208 V 60
Approval
Hz
code