Télécharger Imprimer la page

HQ Power VDLP56 S Serie Mode D'emploi page 5

Publicité

Les langues disponibles
  • FR

Les langues disponibles

In order to connect the fixture to the mains, you have to install a power plug.
Brown = live, blue = neutral, yellow/green = earth.
Connect the fixture to the mains with the power plug. If the device will be directly connected with the
local power supply network, a disconnection switch with a minimum opening of 3 mm at every pole has
to be included in the permanent electrical installation.
Fixing the Clamp
Fix the clamp to the upper part of the mounting bracket. Make sure to tighten the bolt and nut tightly.
Refer to illustration A on page 2.
The Safety Cable
Always secure the device with a secondary attachment. Use the included safety cable. Pass this cable
through the mounting bracket and fix to a secure anchorage point.
5.
Cleaning and Maintenance
All screws should be tightened and free of corrosion.
The housing, visible parts, mounting supports and the installation location (e.g. ceiling, suspension,
trussing) should not be deformed, modified or tampered with e.g. do not drill extra holes in mounting
supports, do not change the location of the connections.
Moving mechanic parts must not show any signs of wear and tear.
The electric power supply cables must not show any damage. Have a qualified technician maintain
the device.
Disconnect the device from the mains prior to maintenance activities.
Wipe the device regularly with a moist, lint-free cloth. Do not use alcohol or solvents.
There are no user-serviceable parts.
Contact your dealer for spare parts if necessary.
6.
Technical Specifications
power supply
power consumption
lamp
dimensions
total weight
max. ambient temperature
max. housing temperature
Use this device with original accessories only. Velleman nv cannot be held responsible in the
event of damage or injury resulting from (incorrect) use of this device. For more info
concerning this product and the latest version of this manual, please visit our website
www.hqpower.eu. The information in this manual is subject to change without prior notice.
© COPYRIGHT NOTICE
The copyright to this manual is owned by Velleman nv. All worldwide rights reserved. No part
of this manual may be copied, reproduced, translated or reduced to any electronic medium or otherwise
without the prior written consent of the copyright holder.
V. 02 – 02/10/2014
VDLP56xxS
max. 230 VAC, 50 Hz
max. 500 W
MFL 300 W / 240 V GX16D (incl.) or GE 300 W / 240 V GX16D
(LAMP300P56S, not incl.) or M40 500 W / 240 V GY9.5 + PAR56
reflector (LAMP500P + VDL56RF, not incl.)
400 x 210 x 210 mm
2 kg
45 °C
190 °C
5
©Velleman nv

Publicité

loading

Ce manuel est également adapté pour:

Vdlp56lbsPar56 packEnsemble par56