Installation of the Housing
Step 1
Remove the air conditioner from it's packaging and slide the air conditioner
out of it's housing.
Step 2
Prepare the hole in the wall so that the bottom of the housing is well
supported, the top has minimum clearace and the air inlet louveres have
clearance as shown. Holes from the outside through to the cavity should
be sealed. The housing should slope down towards the rear by about 5mm
to allow water formed during operation to drain.
Step 3
Install the housing into the wall and secure. Ensure the foam seals
are not damaged. Flash, seal or fill gaps around the inside and
outside to provide satisfactory appearance and protection against
the weather, insects and rodents.
Installations of the unit into the Housing
1
Slide the unit into the housing until it is firmly against the rear of
the housing. Care is required to ensure the foam sealing strips
on the housing remain in position.
2
Connect the air conditioner to the power and coil excess cord
length beneath the air conditioner base or control box.
3
Engage the Chassis Lock into the bottom housing rail and secure
to the base with the screw provided.
4
Remove the front panel from i's carton and plastic bag and fit as
per the Operating Instruction.
5
Switch unit on. Check for operation of the unit and check for
vibration in the installation.
6
Fit the drain chute to the housing and run a drain line to a
suitable location if required.
Installations of the unit into the wall
AIR IN
100mm minimum
OPTION A
AIR IN
AIR IN
AIR OUT
STURDY TIMBER
FRAME
TIMBER FRAMED
WALL OR PARTITION
45° BRICK CUT AWAY
TO CLEAR LOUVRES
BRICK
WALL
AIR IN
LOUVRE
16
NOTE: UNIT MAY BE SUPPORTED BY A
SOLID FRAME FROM BELOW OR
BY A HANGER FROM A SOLID
OVERHEAD SUPPORT.
FLASH OR SEAL AROUND EXTERNAL
WALL FRAME OR ARCHITRAVE
STURDY TIMBER
EXTERNAL SUPPORT
FRAME ALL ROUND
FRAME AT BALANCE
UNIT
POINT OF RAC
ALTERNATIVELY, BRACKETS
TIMBER FRAMED
AS ILLUSTRATED BELOW
WALL OR PARTITION
MAY BE USED.
Preferred method of installation into
a timber framed wall, partition or window.
FLASH OR SEAL AROUND EXTERNAL
WALL FRAME OR ARCHITRAVE
ENSURE LOUVRES
ARE ENTIRELY
OUTSIDE THE WALL.
DRAIN CHUTE
STEADYING BRACKET
(ONE PER SIDE)
SOLID TIMBER SUPPORT
Alternative method of installation if external
support cannot be provided.
45° BRICK CUT AWAY
TO CLEAR LOUVRES
FRONT
BRICK
WALL
100mm
TOP
VIEW
AIR IN
100mm
AIR OUT
OPTION B
DRAIN CHUTE