Télécharger Imprimer la page

T.I.P. EXTREMA 400/11 CX Mode D'emploi page 15

Pompe submersible pour eaux usées

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 17
MALFUNCTION
3. The pump stops
1. The electrical supply does not
after a short time of
operation because
the thermal motor
protection feature
has triggered.
2. Pump or intake openings are blocked
3. Liquid is too viscous.
4. Temperature of the liquid is too high.
5. Pump is running dry.
4. Intermittent or
1. Pump wheel obstructed by solid
irregular operation.
2. Refer to section 3.3.
3. Refer to section 3.4.
4. Mains voltage out of tolerance.
5. Motor or pump wheel defective.
5. Water quantity
1. Refer to section 2.1.
discharged by pump
2. Refer to section 2.2.
is inadequate.
3. Worn pump wheel.
6. The pump does not
1. Floating switch cannot move freely.
cut in or out.
2. Incorrect setting of floating switch.
3. Floating switch defective.
9. Warranty
The present device was manufactured and inspected according to the latest methods. The seller warrants for
faultless material and workmanship in accordance with the legal regulations of the country in which the device
was purchased. The warranty period begins with the day of the purchase and is subject to the provisions below:
Within the period of warranty, all defects which are to be attributable to defective materials or manufacturing will
be eliminated free of charge. Any complaints are to be reported immediately upon their detection.
The warranty claim becomes void in the case of interventions undertaken by the purchaser or by third parties.
Damage resulting from improper handling or operation, incorrect setting-up or storage, inappropriate connection
or installation or Acts of God or other external influences are excluded from warranty.
Parts being subject to wear and tear, such as the pump wheel (impeller) and mechanical shaft seals are excluded
from warranty.
All parts were manufactured using maximum care and high-quality materials and are designed for a long lifecycle.
It should be understood, however, that the wear and tear depends on the kind of use, the intensity of use and the
internals of maintenance. Complying with the installation and maintenance information contained in the present
operating instructions will therefore considerably contribute to a long lifecycle of these wearing parts.
In case of complaints, we reserve the option of repairing or replacing the defective parts or replace the entire
device. Replaced parts will pass into our property.
Claims for liquidated damages are excluded unless they are caused by willful acts or negligence on the side of
the manufacturer.
The warranty does not provide for any claims beyond those referred to above. The warranty claim has to be
evidenced by the purchaser in the form of the submission of the sales receipt. The present warranty commitment
is valid in the country in which the device was purchased.
Please note:
1. Should your device fail to function properly, please verify first whether an operating error or another cause is
present which cannot be attributed to a defect of the device.
2. In case you have to take or send in your defective device for repair, please be sure to enclose the following
documents:
 Sales receipt (sales slip).
 A description of the occurring defect (a description as accurate as possible will expedite the repair work).
3. In case you have to take or send in your defective device for repair, please remove any attached parts which
do not belong to the original condition of the device. If any attached parts of this kind should be missing upon
the return of the device, we shall not be liable for them.
POSSIBLE CAUSE
correspond to the information given
on the type plate.
by solids.
matters.
1. Please use a device complying with GS
(German technical supervisory authority)
to check the voltage of the lines of the
connection cord (safety information to be
observed!).
2. Remove possible congestion.
3. Pump may not be suitable for this liquid.
If feasible, the liquid should be thinned.
4. Make sure that the temperature of the
liquid being pumped does not exceed the
max. admissible value.
5. Eliminate causes of dry-running.
1. Remove solids.
2. Refer to section 3.3.
3. Refer to section 3.4.
4. Make sure that mains voltage matches
that indicated on the type plate.
5. Please contact the customer service
department.
1. Refer to section 2.1.
2. Refer to section 2.2.
3. Please contact the customer service
department.
1. See that floating switch can move freely.
2. Correct floating switch settings.
3. Please contact the customer service
department.
6
ELIMINATION
13

Publicité

loading

Ce manuel est également adapté pour:

1165408-6230168Q831761