3.3.2. Coff ee machines with the ETL mark

4-core machines
220V-240V SINGLE PHASE WITH NEUTRAL WIRE (1-2-3 GROUP MACHINES)
The machine can be connected to power supplies with a single phase of 220-240V. In this case, the Black cable
must be joined to the Red cable, and then connected to the phase in the permanent electrical installation. The
White/Black cable must be connected to the neutral wire. The Green cable must be connected to the earth.
--///
Neutral
Phase (S)
400V SINGLE PHASE WITH NEUTRAL WIRE (1-2-3 GROUP MACHINES)
The machine can be connected to power supplies with three phases and a neutral wire of 400V. In this case, the
Black cable must be connected to one of the three phases, the Red cable to the same, and the White/Black cable
to the neutral wire. The Green cable must be connected to the earth.
--///
Phase (R)
Phase (S)
Phase (T)
Neutral
400V TWO PHASE WITH NEUTRAL WIRE (1-2-3 GROUP MACHINES)
The machine can be connected to power supplies with three phases and a neutral wire of 400V. In this case, the
Black cable must be connected to one of the three phases, the Red cable to a diff erent phase, and the White/Black
cable to the neutral wire. The Green cable must be connected to the earth.
--///
Phase (R)
Phase (S)
Phase (T)
Neutral
110V SINGLE PHASE WITH NEUTRAL WIRE (1-2 GROUP MACHINES)
IMPORTANT: The machines manufactured for use with electrical voltages of
110V have been manufactured with electrical elements specifi cally for that
voltage. They can thus only be installed at a voltage of 110V, as indicated on
the specifi c electrical diagram for these voltages.
The machine can be connected to power supplies with a single phase of 110V. In this case, the Black cable must
be connected to the permanent electrical installation phase, the Red cable must be connected to the same phase
as the Black cable, and the Black/White cable to the neutral wire. The Green cable must be connected to the earth.
--///
Neutral
Phase (R)
INSTALLATION AND OPERATION MANUAL
Black
Red
White/Black Green
Black
Red White/Black Green
Black
Red White/Black Green
Black
Red
White/Black Green
220-240V
220-240V
220-240V
110V