Iberital Expression Two Manuel D'installation Et De Fonctionnement page 62

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 71
IBERITAL
2.11.- RESET THE CONTROL UNIT MACHINE WITH DISPLAY
In machines with display models, the control unit can be reset to the initial factory parameters. To do this turn
the main switch of the machine (position 0) and simultaneously press buttons 1 short coff ee, 1 long coff ee and
continued.
Keep it pressed and move the main switch of the machine in position 1 or 2, is indistinct. Hold it for several seconds
until visulaizar onscreen display PRESET RESET COMPLETE message.
Turn the main switch of the machine in position 0 and drop pulsadores.Al turn the machine we will reset the unit
to factory control unit parameters.
NOTE: Perform this action means losing any customization done on the machine, both in the technical menu and
the user menu. Accountants, visualizations, dosages, date / time and settings, climate control, ...
If your machine does not regulate the temperature by temperature sensor, but does so through the action of a
pressure switch, the display will appear in the following error:
This situation is due to an incorrect selection on the heating menu. In order to eliminate this alarm, follow the steps
indicated in paragraph 2.10, section "C" (INTERRUPTED TEMPERATURE SENSOR), acting like a replacement unit in
question.
Page 62
T.ProbeUnconnect
(not available on all models)