N˚
Code de la pièce
①
TB-A
ALIMENTATION CA
②
TB-A1
COMMANDE DE
③
TB-B
④
CNP501
VANNE À 3 VOIES
⑤
CNP001
⑥
CNP002
⑦
CNP003
⑧
CNP401
Nom de la pièce
#1: L
ENTRÉE
#2: N
#1: L
SORTIE
CHAUFFAGE
#2: N
#1: N
#2: ROBINET MÉLANGEUR_SH (L)
#3: ROBINET MÉLANGEUR_SAH (L)
#4: CHAUDIÈRE (L)
#5: N
#6: L
#7: N
#8: POMPE À EAU (L)
#9: VANNE À 2 VOIES1_NO (L)
#10: VANNE À 2 VOIES1_NC (L)
Sortie de la pompe à eau Zone1 (FSV 4061
= 1)
#11: N
#12: L
#13: VANNE À 2 VOIES2_NO (L)
CHARGE
#14: VANNE À 2 VOIES2_NC (L)
Sortie de la pompe à eau Zone2 (FSV 4061
= 1)
#15: N
#16: L
#17: VANNE À 3 VOIES_NO (L)
#18: VANNE À 3 VOIES_NC (L)
#19: N
#20: L
#21: THERMOSTAT1_C (L)
#22: THERMOSTAT1_H (L)
#23: THERMOSTAT2_C (L)
#24: THERMOSTAT2_H (L)
#25: SOLAIRE_N
#26: SOLAIRE_L
#1: N
#2: PAS DE CONNEXION
#3: VANNE À 3 VOIES_NO (L)
#4: PAS DE CONNEXION
#5: VANNE À 3 VOIES_NC (L)
MC1-A
#1: L
MC2-A
#1: L
MC-COMMUN
#1: N
#1: N
THERMOSTAT DE
#2: PAS DE CONNEXION
CHAUFFAGE
#3: N
FRANCAIS-23
Terminal
Description du terminal
ENTRÉE CA
ENTRÉE CA
SORTIE CA
SORTIE CA
SORTIE CA
SORTIE CA
SORTIE CA
SORTIE CA
SORTIE CA
SORTIE CA
SORTIE CA
SORTIE CA
SORTIE CA
SORTIE CA
SORTIE CA
SORTIE CA
SORTIE CA
SORTIE CA
SORTIE CA
SORTIE CA
SORTIE CA
SORTIE CA
SORTIE CA
SORTIE CA
ENTRÉE CA
ENTRÉE CA
ENTRÉE CA
ENTRÉE CA
ENTRÉE CA
ENTRÉE CA
SORTIE CA
-
SORTIE CA
-
SORTIE CA
SORTIE CA
SORTIE CA
SORTIE CA
SORTIE CA
-
SORTIE CA