ATTENTION : Always remove condensation water from the tube before use or when
the appliance hasn't been used for a long time. The tube can be emptied in a container
or in the sink by pressing the button. When the tube is empty it can be used again.
Never direct the tube towards persons, animals or plants.
IMPORTANT : Make sure the plug isn't in the socket when filling the unit for the first
time or when refilling it.
ATTENTION : let the unit cool down for about 15 minutes before refilling it again.
When the unit gets filled when it is still hot the first drops of water can splash out. Be
very careful when opening the safety fill cap: the cap can get hot during use and the
escaping steam can cause burns.
USING THE VARIABLE STEAM FEATURE
Your steam cleaner has a variable steam feature that allows you to adjust the steam
flow to the job you are doing. The variable steam control is located on the handle.
To increase the steam flow, turn the knob counter clockwise.
To decrease the steam flow , turn it clockwise.
REFILLING THE STEAM CLEANER WITH WATER
Step 1
Remove the plug from the socket.
Step 2
Press the steam button and keep it pressed in until all pressure is gone from
the boiler.
Step 3
Unscrew the safety fill cap carefully by turning it counter clockwise, so all
remaining steam can escape. When all hissing has stopped and the last steam has dis-
appeared you can remove the safety cap. Let the appliance cool down.
ATTENTION : Let the appliance cool down for 15 minutes before refilling it. Filling
the appliance when it is still hot can cause the water to splash out and cause burns.
Therefore always be very careful when filling the appliance and opening the safety
fill cap. The safety fill cap can get very hot during use and the escaping steam can
cause burns.
Step 4
Let the steam cleaner cool down for 15 minutes before filling it again.
Step 5
Fill the water tank by using the funnel.
Step 6
Place the safety fill cap bag on the unit by turning it clockwise.
Step 7
Place the plug in the socket.
Using the steam cleaner with floor brush
Step 1
Place the extension tubes on the handle of the flexible tube. To connect the
extension tubes to the handle or to each other press the button so it fits into the hole.
To disconnect, press the button again and pull the two parts apart.
NOTE : Connect the floor brush to the tubes by using the angle adaptor.
Step 2
When the angle adapter isn't attached to the floor brush, keep the brush