Télécharger Imprimer la page

GiBiDi BE24/115V Instructions Pour L'installation page 22

Publicité

Les langues disponibles

Les langues disponibles

22
UK
14 - GATE TRAVEL LEARNING
The procedure has two phases, completely automatic: the first one of OPENING and CLOSING SPACES
learning and the second one of motors' amperometric values learning.
If using only one motor, it must be connected to the terminals M1.
Intervention of START, PED, PHOTO1, PHOTO2, SAFETY inputs during learning procedure will abort the
procedure and it will be necessary to repeat it from the beginning.
During learning procedure FLASHING LIGHT / WARNING LIGHT will be on.
Travel learning movement is slowed down (50%).
Learning procedure cannot be executed while running on battery.
Learning procedure:
Release the operators and move the gates to halfway their travel.
Ÿ
Lock the operators.
Ÿ
Check that the mechanical opening and closing stops are present on the ground (KUDA-AGO) or on the
Ÿ
operator (SERRA320-SNAPPER).
Remove any obstacles in the range of action of the automated device.
Ÿ
Check that leds L3, L4, L5 and L8 are on.
Ÿ
Press and release MEMO button.
Ÿ
Led L7 will come on, after 30 seconds of no user interaction the control board will quit learning procedure.
Ÿ
Within 30 seconds press again MEMO button in order to choose operator type. At the first stroke L7 will blink
Ÿ
once every 4 seconds and that means KUDA-AGO424E-AGO624E is the installed operator; at the second stroke
L7 will blink twice every 4 seconds and that means SERRA320-SNAPPER-AGO424E/S-AGO624E/S is the
installed operator. The operator selection sequence is cyclic.
Press button 1 of the radio control or give a START pulse from the terminal board.
Ÿ
Check that motors' movement is in the correct direction (at the beginning in opening). On the contrary, block
Ÿ
the learning cycle with any safety device, invert the motor cables and repeat the procedure.
Movements during learning with 2 motors:
• Motor 1 opens until meeting the mechanical end-stops.
• Motor 2 opens until meeting the mechanical end-stops .
• 5 seconds pause.
• Motor 2 closes until meeting the mechanical end-stops.
• Motor 1 closes until meeting the mechanical end-stops.
• Full open-close cycle.
• End of learning; L7 will goes off.
Movements during learning with 1 motor:
• Motor 1 opens until meeting the mechanical end-stops.
• 5 seconds pause .
• Motor 1 closes until meeting the mechanical end-stops.
• It makes a complete manoeuvre, opening, 5 sec. pause and closing.
• End of learning; L7 goes off.
In case the learning procedure cannot be completed, please check LED L7 status (chapter 8).