Télécharger Imprimer la page

Indel Webasto Marine BI36 Instructions Pour L'installation Et L'utilisation page 29

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 81
User Manual
8 Dimensions
Model
Width
(mm) [W]
BI 29 Dual 340
BI 36
240
BI 40
395
BI 41 Dual 340
BI 53F
425
BI 75
425
BI 92 Dual 480
NOTES:
REM: The product is provided with the possiblity of moving the compressor unit based on the length of
the supplied hoses.
1: This dimension indicates the space which is needed for hose output from the product, in order to bend
them if necessary.
AS PER REGULATIONS AND FOR PROPER OPERATION, THE WALLS OUTSIDE OF THE REGRIGERATOR
SHOULD BE SET AT THE FOLLOWING DISTANCES FROM THE INTERNAL WALLS OF THE UNIT: 20mm ON
WALLS WHERE THE COMPRESSOR IS NOT PRESENT AND 50MM ON THE WALLS WHERE THE COMPRESSOR
IS PRESENT. IF THESE RULES CANNOT COMPLIED WITH, THE MINIMUM DISTANCE MEASUREMENTS MUST
BE 5mm AND THE MATERIALS WITH WHICH THE WALLS ARE MADE MUST BE EXPLOSION PROOF.
Length (mm)
Depth (mm)
[L]
[D]
496+165*
330
438
550+165*
395+165*
380
496
450+165*
645
465+165*
645
465+165*
801
455+165*
Door
Cut-Out
Thickness
(mm) W:H
(mm) [S]
35 included 344:500
35 included 442:244
40 included 399:399
13 included 344:500
/
429:649
/
429:649
/
484:805
1
Top Edge
Hoses
Notes
(mm) W:L
343:499
/
REM
/
+25
REM
415:415
+20
REM
343:499
/
REM
430:648
+15
REM
430:648
+15
REM
484:804
+25
REM
29

Publicité

loading

Ce manuel est également adapté pour:

Bi29 dualBi40Bi41 dualBi53fBi75Bi92 dual