User Manual
Excess ice on the
evaporator.
The refrigerator cools too
much.
The compressor is noisier
than normal.
The fan/s is/are noisier than
normal.
The internal light does not
switch on.
Door/Drawer not closing
properly.
For more complicated defects requiring specialised assistance, please contact Indel
Webasto Marine S.r.l. Italia or your nearest Isotherm retailer.
Moisture infiltrations in the
refrigerator.
The thermostat sensor is
too covered or incorrectly
positioned
The compressor is not
properly secured on its
support or it is touching the
wall.
The fan structure is bent or
the fan is broken.
Polarity reversed or broken
bulb.
Incorrect position of hinges or
deformed gasket.
Check the conditions of the gasket on
all four sides of the door. The gasket
must close perfectly on the unit. If the
formation of ice is thicker on one side,
most likely there is moisture infiltration in
the refrigerator is coming from that side.
Use a moderate heat source to model the
gasket into position. If the gasket cannot
be modelled, replace the entire door.
The end of the sensor must be in contact
with the evaporator. Set the sensor in
the correct position. If the refrigerator
continues to cool too much, replace the
thermostat.
Check that compressor screws are properly
tightened and that nothing is in contact
with it. The compressor vibrates and, if
something is in contact with it, vibrations
increase.
Remove the clamps/screws used to secure
the fan. Replace if the fan continues to
make noise. Make sure that all of the fan
is intact. Replace if one or more fins is
missing.
Check bulb polarity. Replace light bulb if
polarity is correct.
Re-position hinges so that the door closes
correctly. Use a moderate heat source
to remodel the gasket. Replace door if
problem persists. In the case of drawer
refrigerators, use the adjustable guides to
align the door.
27