Guidance and manufacturer's declaration - electromagnetic emissions. The BW-SC2W and
BW-SC6W are intended for use in an electromagnetic environment specified below. The custom-
er or the user of the BW-SC2W and BW-SC6W should ensure that it is used such an environment.
Emissions test
Compliance
RF emissions
Group 1
CISPR 11
RF emissions
Class B
CISPR 11
Harmonic emissions
Class A
IEC 61000-3-2
Voltage fluctuations/
flicker emissions
Complies
IEC 61000-3-3
Recommended separation distances between portable and mobile RF communications equipment
and the BW-SC2W and BW-SC6W. The BW-SC2W and BW-SC6W are intended for use in an electromagnet-
ic environment in which radiated RF disturbances are controlled. The customer or the user of the BW-SC2W
and BW-SC6W can help prevent electromagnetic interference by maintaining a minimum distance between
portable and mobile RF communications equipment (transmitters) and the BW-SC2W and BW-SC6W as
recommended below, according to the maximum output power of the communications equipment.
Rated maximum output
of transmitter
w
150 MHz to 80 MHz
d =
0.01
0.1
1
10
100
For transmitters rates at a maximum output power not listed above, the recommended separation distance d
in meters (m) can be estimated using the equation applicable to the frequency of the transmitter, where P is
the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer.
NOTE 1 At 80 MHz and 800MHz, the reparation distance for the higher frequency range applies.
NOTE 2 these guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption
and reflection from structures, objects and people.
76
BewellConnect - BW-SC2 W / BW-SC3 W / BW-SC4 W / BW-SC6 W - User Manual - 082017
Electromagnetic environment - guidance
The BW-SC2W and BW-SC6W use RF energy only
for their internal function. Therefore, their RF
emissions are very low and are not likely to cause
any interference in nearby electronic equipment.
-
The BW-SC2W and BW-SC6W are suitable for
use in all establishments, including domestics
and those directly connected to the public
low-voltage power supply network that supplies
buildings used for domestic purposes.
Separation distance according to
frequency of transmitter m
80 MHz to 800 MHz
800 MHz to 2.5 GHz
[ 3.5
[ 3.5
d =
d =
] √
] √
P
P
V1
V1
0.12
0.12
0.38
0.38
1.2
1.2
3.8
3.8
12
12
[ 7
] √
P
E1
0.23
0.73
2.3
7.3
23
BewellConnect - BW-SC2 W / BW-SC3 W / BW-SC4 W / BW-SC6 W - User Manual - 082017