Note: The air conditioner stops if the room temperature is lower than selected
temperature.
VENTILATING YOUR ROOM
• Press MODE button repeatedly until the FAN indicator lights up.
• In ventilation mode the room air is circulated, but not cooled.
• Press SPEED button repeatedly to select the fan speed as desired.
DRYING YOUR ROOM
• Press MODE button on the control panel or remote control, the dry indicator
lights up. The fan speed is unable to select. User should connect the hose to
the drain outlet at the bottom of the unit.
Note: In this mode, the fan speed switches over to low speed and cannot be
selected.
SLEEP MODE
•
The sleep button can only be set in cooling mode.
•
The machine enters sleep mode, all lights are dimmed at the same time, and
the buzzer is disabled in sleep mode:
– 1 hour after sleep mode is turned ON, the set temperature will automatically
increase by 1°C, and after another hour, the set temperature will automati-
cally increase by 1°C.
AUTOMATIC DEFROST
At low room temperatures, frost may build up at the evaporator during operation.
The unit will automatically start defrosting and the POWER LED blinking. The de-
frost control sequence is as follows:
A. When the unit operates in the cooling and drying operation, and the ambient
temperature sensor senses the evaporator coil temperature is below -1°C, after the
compressor will stop operating for 10 minutes or the coil temperature up to 7°C,
the unit restart to cool operating mode.
B. When the unit operates in the drying operation, once the coil temperature
sensor senses the temperature of the evaporator is below 40°C and the differential
temperature between coil temperature and room temperature is below 19°C after
the compressor operation for 20 minutes, the unit start defrosting for 5 minutes
and the power indicator blinking.
CHILL 12 CONNECTED · AC2B-12000C
15
EN